Comparison Between Patent Ductus Arteriosus Stent and Modified Blalock-Taussig Shunt as Palliation for Infants With Ductal-Dependent Pulmonary Blood Flow: Insights From the Congenital Catheterization Research Collaborative.
摘要:
Infants with ductal-dependent pulmonary blood flow may undergo palliation with either a patent ductus arteriosus (PDA) stent or a modified Blalock-Taussig (BT) shunt. A balanced multicenter comparison of these 2 approaches is lacking. Infants with ductal-dependent pulmonary blood flow palliated with either a PDA stent or a BT shunt from January 2008 to November 2015 were reviewed from the 4 member centers of the Congenital Catheterization Research Collaborative. Outcomes were compared by use of propensity score adjustment to account for baseline differences between groups. One hundred six patients with a PDA stent and 251 patients with a BT shunt were included. The groups differed in underlying anatomy (expected 2-ventricle circulation in 60% of PDA stents versus 45% of BT shunts; P=0.001) and presence of antegrade pulmonary blood flow (61% of PDA stents versus 38% of BT shunts; P<0.001). After propensity score adjustment, there was no difference in the hazard of the primary composite outcome of death or unplanned reintervention to treat cyanosis (hazard ratio, 0.8; 95% confidence interval [CI], 0.52-1.23; P=0.31). Other reinterventions were more common in the PDA stent group (hazard ratio, 29.8; 95% CI, 9.8-91.1; P<0.001). However, the PDA stent group had a lower adjusted intensive care unit length of stay (5.3 days [95% CI, 4.2-6.7] versus 9.19 days [95% CI, 7.9-10.6]; P<0.001), a lower risk of diuretic use at discharge (odds ratio, 0.4; 95% CI, 0.25-0.64; P<0.001) and procedural complications (odds ratio, 0.4; 95% CI, 0.2-0.77; P=0.006), and larger (152 mm2/m2 [95% CI, 132-176] versus 125 mm2/m2 [95% CI, 113-138]; P=0.029) and more symmetrical (symmetry index, 0.84 [95% CI, 0.8-0.89] versus 0.77 [95% CI, 0.75-0.8]; P=0.008] pulmonary arteries at the time of subsequent surgical repair or last follow-up. In this multicenter comparison of palliative PDA stent and BT shunt for infants with ductal-dependent pulmonary blood flow adjusted for differences in patient factors, there was no difference in the primary end point, death or unplanned reintervention to treat cyanosis. However, other markers of morbidity and pulmonary artery size favored the PDA stent group, supporting PDA stent as a reasonable alternative to BT shunt in select patients.
收起
展开
DOI:
10.1161/CIRCULATIONAHA.117.029987
被引量:
年份:
1970


通过 文献互助 平台发起求助,成功后即可免费获取论文全文。
求助方法1:
知识发现用户
每天可免费求助50篇
求助方法1:
关注微信公众号
每天可免费求助2篇
求助方法2:
完成求助需要支付5财富值
您目前有 1000 财富值
相似文献(469)
参考文献(0)
引证文献(66)
来源期刊
影响因子:暂无数据
JCR分区: 暂无
中科院分区:暂无