Tracking of Noise Tolerance to Measure Hearing Aid Benefit.

来自 PUBMED

作者:

Kuk FSeper ELau CCKorhonen P

展开

摘要:

The benefits offered by noise reduction (NR) features on a hearing aid had been studied traditionally using test conditions that set the hearing aids into a stable state of performance. While adequate, this approach does not allow the differentiation of two NR algorithms that differ in their timing characteristics (i.e., activation and stabilization time). The current study investigated a new method of measuring noise tolerance (Tracking of Noise Tolerance [TNT]) as a means to differentiate hearing aid technologies. The study determined the within-session and between-session reliability of the procedure. The benefits provided by various hearing aid conditions (aided, two NR algorithms, and a directional microphone algorithm) were measured using this procedure. Performance on normal-hearing listeners was also measured for referencing. A single-blinded, repeated-measures design was used. Thirteen experienced hearing aid wearers with a bilaterally symmetrical (≤10 dB) mild-to-moderate sensorineural hearing loss participated in the study. In addition, seven normal-hearing listeners were tested in the unaided condition. Participants tracked the noise level that met the criterion of tolerable noise level (TNL) in the presence of an 85 dB SPL continuous discourse passage. The test conditions included an unaided condition and an aided condition with combinations of NR and microphone modes within the UNIQUE hearing aid (omnidirectional microphone, no NR; omnidirectional microphone, NR; directional microphone, no NR; and directional microphone, NR) and the DREAM hearing aid (omnidirectional microphone, no NR; omnidirectional microphone, NR). Each tracking trial lasted 2 min for each hearing aid condition. Normal-hearing listeners tracked in the unaided condition only. Nine of the 13 hearing-impaired listeners returned after 3 mo for retesting in the unaided and aided conditions with the UNIQUE hearing aid. The individual TNL was estimated for each participant for all test conditions. The TNT index was calculated as the difference between 85 dB SPL and the TNL. The TNT index varied from 2.2 dB in the omnidirectional microphone, no NR condition to -4.4 dB in the directional microphone, NR on condition. Normal-hearing listeners reported a TNT index of -5.7 dB using this procedure. The averaged improvement in TNT offered by the NR algorithm on the UNIQUE varied from 2.1 dB when used with a directional microphone to 3.0 dB when used with the omnidirectional microphone. The time course of the NR algorithm was different between the UNIQUE and the DREAM hearing aids, with the UNIQUE reaching a stable TNL sooner than the DREAM. The averaged improvement in TNT index from the UNIQUE directional microphone was 3.6 dB when NR was activated and 4.4 dB when NR was deactivated. Together, directional microphone and NR resulted in a total TNT improvement of 6.5 dB. The test-retest reliability of the procedure was high, with an intrasession 95% confidence interval (CI) of 2.2 dB and an intersession 95% CI of 4.2 dB. The effect of the NR and directional microphone algorithms was measured to be 2-3 and 3.6-4.4 dB, respectively, using the TNT procedure. Because of its tracking property and reliability, this procedure may hold promise in differentiating among some hearing aid features that also differ in their time course of action.

收起

展开

DOI:

10.3766/jaaa.16053

被引量:

1

年份:

2017

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(356)

参考文献(0)

引证文献(1)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读