Echo-planar spectroscopic imaging with dual-readout alternated gradients (DRAG-EPSI) at 7 T: Application for 2-hydroxyglutarate imaging in glioma patients.

来自 PUBMED

作者:

An ZTiwari VGanji SKBaxter JLevy MPinho MCPan EMaher EAPatel TRMickey BEChoi C

展开

摘要:

To develop echo-planar spectroscopic imaging (EPSI) with large spectral width and accomplish high-resolution imaging of 2-hydroxyglutarate (2HG) at 7 T. We designed a new EPSI readout scheme at 7 T. Data were recorded with dual-readout alternated gradients and combined according to the gradient polarity. Following validation of its performance in phantoms, the new readout scheme, together with previously reported 2HG-optimized magnetic resonance spectroscopy (point-resolved spectroscopy echo time of 78 ms), was used for time-efficient and high-resolution imaging of 2HG and other metabolites in five glioma patients before treatment. Unsuppressed water, acquired with EPSI, was used as reference for multichannel combination, eddy-current compensation, and metabolite quantification. Spectral fitting was conducted with the LCModel using in-house calculated basis sets. Using a readout gradient strength of 9.5 mT/m and slew rate of 90 mT/m/ms, dual-readout alternated gradients EPSI permitted 1638-Hz spectral width with 6 × 6 mm2 in-plane resolution at 7 T. Phantom data indicated that dual-readout alternated gradients EPSI provides proper metabolite signals and induces much less frequency drifts than conventional EPSI. For a spatial resolution of 0.5 mL, 2HG was detected in tumors with precision (Cramer-Rao lower bound < 10%). The 2HG was estimated to be 2.3 to 3.3 mM in tumors of three patients with biopsy-proven isocitrate dehydrogenase (IDH) mutant gliomas. The 2HG was undetectable in an IDH wild-type glioblastoma. For a radiographically suggested glioma, the estimated 2HG of 2.3 ± 0.2 mM (Cramer-Rao lower bound < 10%) indicated that the lesion may be an IDH mutant glioma. The data indicated that the dual-readout alternated gradients EPSI can provide reliable high-resolution imaging of 2HG in glioma patients at 7 T in vivo. Magn Reson Med 79:1851-1861, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

收起

展开

DOI:

10.1002/mrm.26884

被引量:

18

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(315)

参考文献(35)

引证文献(18)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读