Beyond HbA1c.

来自 PUBMED

作者:

Bloomgarden Z

展开

摘要:

It can scarcely be denied that the supreme goal of all theory is to make the irreducible basic elements as simple and as few as possible without having to surrender the adequate representation of a single datum of experience. The diaTribe Foundation convened a meeting on the topic of glycemic outcomes beyond HbA1c on 21 July 2017, in Bethesda (MD, USA), focusing on potential uses of continuous glucose monitoring (CGM). Understanding patterns of glycemia in people with diabetes has long been a focus of approaches to improving treatment, and over the past few years this has become an available modality for clinical practice. Glucose levels are not the only biologic parameters affecting HbA1c levels; HbA1c changes with anemia or, more subtly, with changes in rates of erythrocyte turnover not reflected in hemoglobin levels outside the normal range. Renal disease often is associated with lower HbA1c than would be predicted based on an individual's glycemic levels. Furthermore, HbA1c levels tend to increase with age and are higher in some ethnic groups; for example, people of African ethnicity have higher HbA1c levels than people of Northern European descent. Indeed, we have argued that even as a measure of mean glycemia HbA1c is inherently imprecise. Overall, for some 20% of people with diabetes, HbA1c levels are substantially higher, or substantially lower, than those that would be predicted from mean blood glucose levels. If one recognizes that HbA1c is, at best, a partial measure of mean glycemic exposure, one must surely accept that HbA1c does not reflect variability within a day, from day to day, and from period to period. Many glucose-lowering medicines, particularly the sulfonylureas and insulin, cause hypoglycemia, with consequent negative effects on quality of life and patient-reported outcomes, as well as association with weight gain and adverse macrovascular outcome; hypoglycemia will, of course, not be captured by HbA1c measurement. Based on these considerations, HbA1c may be more limited than generally recognized as a surrogate marker of optimal diabetes treatment, leading the European Medicines Agency to consider relying less on this measure, with the implication that novel approaches will be required for clinical practice and for clinical trials in developing future medicines. In surveys performed by a market research company (dQ&A Market Research, San Francisco, CA, USA) and reported at the Bethesda meeting, among >3000 people with type 1 (T1D) or type 2 (T2D) diabetes both receiving and not receiving insulin, the majority reported a sense that their diabetes care is not very successful and that too much of their time was spent outside the 70-180 mg/dL (3.9-10.0 mEq/L) range. Although self-monitoring of capillary blood glucose (SMBG) is an important tool for patients to use in understanding glycemic excursions, CGM offers a far superior technology in this regard and can avoid the erroneous conclusions often accompanying the use of the inherently indirect measurement of HbA1c. Duration and severity of hypoglycemia may come to be considered important medication efficacy measures, rather than just being considered safety outcomes. Glucose cut-off levels suggested at the meeting may be: <54 mg/dL (3.0 mEq/L) for severe hypoglycemia, <70 mg/dL (3.9 mEq/L) for low blood glucose levels, >180 mg/dL (10.0 mEq/L) for high blood glucose levels, and >240 mg/dL (13.3 mEq/L) for serious high blood glucose levels. An important part of both SMBG and CGM technologies will be the development of data transmission and storage modalities to better provide feedback to people with diabetes and health care providers in adjusting a variety of treatments, as well as their growing use in insulin dose adjustment algorithms; important in such approaches will be the integration of SMBG with CGM to recognize potential measurement errors and to improve the accuracy and assurance of patients and providers that the CGM results are accurate, a particular concern for readings in the hypoglycemia range, but remaining an issue throughout the clinical glycemia range. However, one must recognize that many commercially available SMBG instruments also fail to exhibit required accuracy, and that the indirect relationship between HbA1c and blood glucose suggests that HbA1c is at best limited in its portrayal of glycemic exposure. All these modalities play a role, but the use of CGM appears crucial to the development of better approaches to clinical treatment with multiple views allowing understanding of patterns of glycemic exposure. We look forward to further improvements in this methodology.

收起

展开

DOI:

10.1111/1753-0407.12590

被引量:

6

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(3161)

参考文献(0)

引证文献(6)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读