Therapeutic analysis of Intrabeam-based intraoperative radiation therapy in the treatment of unicentric breast cancer lesions utilizing a spherical target volume model.

来自 PUBMED

作者:

Schwid MDonnelly EDZhang H

展开

摘要:

It is postulated that the outcomes in treating breast cancer with intraoperative radiotherapy (IORT) would be affected by the residual cancer cell distribution within the tumor bed. The three-dimensional (3D) radiation doses of IntrabeamTM (IB) IORT with a 4-cm spherical applicator at the energy of 50 and 40 kV were calculated. The modified linear quadratic model (MLQ) was used to estimate the radiobiological responses of the cancer cells and interspersed normal tissues with various radiosensitivities. By comparing the average survival fraction of normal tissues in IB-IORT and uniform dose treatment for the same level of cancer cell killing, the therapeutic ratios (TRs) were derived. The equivalent uniform dose (EUD) was found to increase with the prescription dose and decrease with the cancer cell infiltrating distance. For 50 kV beam at the 20 Gy prescription dose, the EUDs are 18.03, 16.49 and 13.56, 11. 29, and 9.28 Gy respectively, for 1.5, 3.0, 6.0, 9, and 15.0 mm of the cancer cell infiltrating distance into surrounding tissue. The dose rate of 50 kV is at least 1.87× higher than that of 40 kV beam. The EUDs of 50 kV beam are up to 15% higher than that of the 40 kV beam. The TR increases with the prescription dose, but decreases with the distance of cancer cell infiltration distance. Average TRs of 50 kV beam are up to 30% larger than that of 40 kV beam. In conclusion, IB-IORT can provide a possible therapeutic advantage on sparing more normal tissue compared with the External Beam IORT (EB-IORT) for shallowly populated unicentric breast lesion. Our data suggest that IB-IORT dose size should be adjusted based on the individual patient's cancer cell infiltrating distance for delivering an effective dose, one dose-fits-all regimen may have undertreated some patients with large cancer infiltrating distance.

收起

展开

DOI:

10.1002/acm2.12140

被引量:

4

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(151)

参考文献(29)

引证文献(4)

来源期刊

Journal of Applied Clinical Medical Physics

影响因子:2.241

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读