Comparison of Performance of Improved Serum Estimators of Glomerular Filtration Rate (GFR) to (99m)Tc-DTPA GFR Methods in Patients with Hepatic Cirrhosis.

来自 PUBMED

作者:

Haddadin ZLee VConlin CZhang LCarlston KMorrell GKim DHoffman JMMorton K

展开

摘要:

Glomerular filtration rate (GFR) measurements are critical in patients with hepatic cirrhosis but potentially erroneous when based on serum creatinine. New equations for estimated GFR (eGFR) have shown variable performance in cirrhotics, possibly because of inaccuracies in reference methods for measured GFR (mGFR). The primary objective was to compare the performance of 4 improved eGFR equations with a 1-compartment, 2-sample plasma slope intercept 99mTc-DTPA mGFR method to determine whether any of the eGFR calculations could replace plasma 99mTc-DTPA mGFR in patients with cirrhosis. The secondary objective was to test the hypothesis that mGFR using voluntary voided urine collections introduces error compared with plasma-only methods. Methods: Fifty-four patients with hepatic cirrhosis underwent mGFR determinations from 2 plasma samples at 1 and 3 h after intravenous administration of 185 MBq of 99mTc-DTPA. GFR was also generated by a UV/P calculation derived from blood and urine samples. These mGFRs were compared with the eGFRs generated by 4 estimating equations: MDRD (Modified Diet in Renal Disease), CKD-EPI (Chronic Kidney Disease-Epidemiology Collaboration) (serum creatinine [SCr]), CKD-EPI (cystatin [CysC]), and CKD-EPI (CysC+SCr). eGFRs were compared with mGFRs by Pearson correlation, precision, bias, percentage bias, and accuracy (eGFRs varying by <10% [p10], <20% [p20] or <30% [p30] from the corresponding mGFR). Results: All eGFRs showed poorer performance when the UV/P 99mTc-DTPA mGFR was used as the reference than when the plasma 99mTc-DTPA mGFR was used. When compared with the plasma 99mTc-DTPA mGFR method, the performance of all eGFR equations was superior to most published reports. There was a moderately good positive correlation between eGFRs and mGFRs. When compared with plasma 99mTc-DTPA mGFR, precision of eGFRs was in the range of 14-20 mL/min and showed a negligible bias. Compared with the plasma 99mTc-DTPA mGFR, CKD-EPI (CysC+SCr) showed the best overall performance and accuracy, at 85.19% (p30), 75.93% (p20), and 42.59% (p10). Conclusion: Estimating equations for measuring eGFR performed better than in most published reports, attributable to use of the plasma 99mTc-DTPA mGFR method as a reference. CKD-EPI (CysC+SCr) eGFR showed the best overall performance. However, more discriminating methods may be required when accurate GFR measurements are necessary. mGFR measurements using urine collections may introduce error compared with plasma-only methods.

收起

展开

DOI:

10.2967/jnmt.116.180851

被引量:

3

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(867)

参考文献(28)

引证文献(3)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读