Filmless methods for quality assurance of Tomotherapy using ArcCHECK.

来自 PUBMED

作者:

Yang BWong WKGeng HLam WWHo YWKwok WMCheung KYYu SK

展开

摘要:

Tomotherapy delivers an intensity-modulated radiation therapy (IMRT) treatment by the synchronization of gantry rotation, multileaf collimator (MLC), and couch movement. This dynamic nature makes the quality assurance (QA) important and challenging. The purpose of this study is to develop some methodologies using an ArcCHECK for accurate QA measurements of the gantry angle and speed, MLC synchronization and leaf open time, couch translation per gantry rotation, couch speed and uniformity, and constancy of longitudinal beam profile for a Tomotherapy unit. Four test plans recommended by AAPM Task Group 148 (TG148) and the manufacturer were chosen for this study. Helical and static star shot tests are used for checking the leaves opened at the expected gantry angles. Another helical test is to verify the couch traveled the expected distance per gantry rotation. The final test is for checking the couch speed constancy with a static gantry. ArcCHECK can record the detector signal every 50 ms as a movie file, and has a virtual inclinometer for gantry angle measurement. These features made the measurement of gantry angle and speed, MLC synchronization and leaf open time, and longitudinal beam profile possible. A shaping parameter was defined for facilitating the location of the beam center during the plan delivery, which was thereafter used to calculate the couch translation per gantry rotation and couch speed. The full width at half maximum (FWHM) was calculated for each measured longitudinal beam profile and then used to evaluate the couch speed uniformity. Furthermore, a mean longitudinal profile was obtained for constancy check of field width. The machine trajectory log data were also collected for comparison. Inhouse programs were developed in MATLAB to process both the ArcCHECK and machine log data. The deviation of our measurement results from the log data for gantry angle was calculated to be less than 0.4°. The percentage differences between measured and planned leaf open time were found to be within 0.5% in all the tests. Our results showed mean values of MLC synchronization of 0.982, 0.983, and 0.995 at static gantry angle 0°, 45°, and 135°, respectively. The mean value of measured couch translation and couch speed by ArcCHECK had less than 0.1% deviation from the planned values. The variation in the value of FWHM suggested the couch speed uniformity was better than 1%. The mean of measured longitudinal profiles was suitable for constancy check of field width. Precise and efficient methods for measuring the gantry angle and speed, leaf open time, couch translation per gantry rotation, couch speed and uniformity, and constancy of longitudinal beam profile of Tomotherapy using ArcCHECK have been developed and proven to be accurate compared with machine log data. Estimation of the Tomotherapy binary MLC leaf open time is proven to be precise enough to verify the leaf open time as small as 277.8 ms. Our method also makes the observation and quantification of the synchronization of leaves possible.

收起

展开

DOI:

10.1002/mp.12009

被引量:

1

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(393)

参考文献(0)

引证文献(1)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读