Hybrid isocenter technique for Gamma-Knife Perfexion treatment of trigeminal neuralgia.

来自 PUBMED

作者:

Cho YBLaperriere NHodaie MChung C

展开

摘要:

Gamma-Knife (GK), Perfexion (PFX) has 8 sectors that can be blocked compared with the older model 4C, which has 201 independent source blocking options using plugs. This limits the ability of PFX to shape a single isocenter plan, such as trigeminal neuralgia. In this retrospective review and prospective re-planning comparison study of trigeminal neuralgia radiosurgery plans, a hybrid isocenter technique (HIT) is compared with single isocenter GK radiosurgery plans on 2 models (4C and PFX) dosimetric parameters. With ethics approval, patients treated on 4C (n = 100) and PFX (n = 50) between 2005 and 2014 for trigeminal neuralgia were reviewed. All clinical plans were produced using 1 isocenter with a 4-mm collimator and a prescription dose of 80Gy at 100% while limiting brainstem dose to < 15Gy ( [Formula: see text] ). Dose shaping was performed using plugs in 4C and sector blocking in PFX to optimize the plan, if required. Re-planning using HIT was retrospectively attempted for PFX plans with brainstem dose > 15Gy. In the implementation of HIT, we used 2 shots at the same isocenter, but with different sector block configuration and weights, to further reduce brainstem dose while optimizing dose coverage of the nerve. Planning parameters such as dose to the treated nerve, brainstem, and surrounding tissue were compared between the clinical plans and the new plans with HIT. Source blocking was applied in 66/100 4C plans with mean blocked sources of 40.2/201 (ranging 1 to 99) and in 36/50 PFX plans with mean blocked sectors of 2.2/8 (1 to 4). There is no significant differences in mean dose, integral dose, irradiated volume of the treated nerve between 4C, and PFX plans. The 4C plans had smaller irradiated volume of tissue (90.6mm3) than PFX plans (103.5mm3) (p < 0.001). The irradiated volume of tissue increases by 17% when half of the sources are blocked for both 4C and PFX plans. In 9/50 PFX plans, brainstem [Formula: see text] was 15.8Gy on average (15.2 to 16.5Gy) and [Formula: see text] was 12.2Gy (11.4 to 13.2Gy). Re-plans of these 9 cases using HIT resulted in a significant reduction in [Formula: see text] to 13.5Gy (12.2 to 15.1) and [Formula: see text] to 10.5Gy (8.1 to 12.2) (p < 0.001). There was < 1% difference between the original PFX and re-planned HIT plans in dose to the nerve, and treatment time (p = 0.186). It is noted that the increase in the irradiated volume of tissue is proportional to the use of source blocking. Larger irradiated volume may be a reason that higher pain control rate and complication rate at the same time. Hybrid isocenter technique results in greater sparing of the brainstem without compromise in the dose to the nerve or treatment time on GK PFX planning for the treatment of trigeminal neuralgia.

收起

展开

DOI:

10.1016/j.meddos.2016.05.002

被引量:

0

年份:

2016

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(171)

参考文献(0)

引证文献(0)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读