Body Fat Analysis in Predialysis Chronic Kidney Disease: Multifrequency Bioimpedance Assay and Anthropometry Compared With Dual-Energy X-Ray Absorptiometry.

来自 PUBMED

作者:

Ravindranath JPillai PPParameswaran SKamalanathan SKPal GK

展开

摘要:

Body composition analysis is required for accurate assessment of nutritional status in patients with predialysis chronic kidney disease (CKD). The reference method for assessing body fat is dual-energy X-ray absorptiometry (DXA), but it is relatively expensive and often not available for widespread clinical use. There is only limited data on the utility of less expensive and easily available alternatives such as multifrequency bioimpedance assay (BIA) and skinfold thickness (SFT) measurements for assessing body fat in predialysis CKD. The study intends to assess the utility of BIA and SFT in measuring body fat compared to the reference method DXA in subjects with predialysis CKD. Body composition analysis was done in 50 subjects with predialysis CKD using multifrequency BIA, SFT, and DXA. The agreement between the body fat percentages measured by reference method DXA and BIA/SFT was assessed by paired t-test, intraclass correlation coefficients (ICCs), regression, and Bland-Altman plots. Percentage of body fat measured by BIA was higher compared to the measurements by DXA, but the difference was not significant (30.44 ± 9.34 vs. 28.62 ± 9.00; P = .071). The ICC between DXA and BIA was 0.822 (confidence interval: 0.688, 0.899; P = .000). The mean values of body fat percentages measured by anthropometry (SFT) was considerably lower when compared to DXA (23.62 ± 8.18 vs. 28.62 ± 9.00; P = .000). The ICC between DXA and SFT was .851 (confidence interval: 0.739, 0.915; P = .000). Bland-Altman plots showed that BIA overestimated body fat by a mean of 1.8% (standard deviation, 6.98), whereas SFT underestimated body fat by 5% (standard deviation, 4.01). Regression plots showed a better agreement between SFT and DXA (R(2) = .79) than BIA (R(2) = .50). Overall, SFT showed better agreement with the DXA. Body mass index (BMI) showed a moderate positive correlation with body fat measured by DXA whereas serum albumin failed to show good correlation. SFT showed relatively better agreement with the reference method DXA, compared to BIA. SFT can be used as a tool for assessing nutritional status in predialysis patients with CKD.

收起

展开

DOI:

10.1053/j.jrn.2016.04.002

被引量:

4

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(490)

参考文献(0)

引证文献(4)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读