Changes in the Pacemaker Rate After Transition From Edwards SAPIEN XT to SAPIEN 3 Transcatheter Aortic Valve Implantation: The Critical Role of Valve Implantation Height.

来自 PUBMED

作者:

De Torres-Alba FKaleschke GDiller GPVormbrock JOrwat SRadke RReinke FFischer DReinecke HBaumgartner H

展开

摘要:

The aim of this study was to analyze the pacemaker implantation rate (PMIR) with the new balloon-expandable Edwards SAPIEN 3 valve (S3) and the factors associated with it. The introduction of the S3 for transcatheter aortic valve replacement (TAVR) has led to a reduction in paravalvular regurgitation. There are, however, concerns that the new design may increase the PMIR. The first 206 patients treated with the S3 were compared with 371 preceding patients treated with SAPIEN XT valves. Patients who previously underwent pacemaker or implantable cardioverter defibrillator implantation or transapical and valve-in-valve procedures were excluded from the analysis. All patients were monitored for at least 7 days. Previous and new conduction abnormalities were documented, and prosthesis implantation height was assessed for the S3. There were no significant differences in baseline characteristics between groups. The PMIR was, however, significantly higher for the S3 (19.1% vs. 12.2%; p = 0.046). The mean implantation height was significantly lower in patients requiring PMI (67%/33% vs. 72%/28% aortic/ventricular stent extension, p = 0.032). On multivariate regression analysis, implantation height was the only independent predictor of PMI (odds ratio: 0.94 [95% confidence interval: 0.90 to 0.99]; p = 0.009). It increased from 68%/32% to 75%/25% when comparing the first with the second half of S3 implantations (p < 0.0001). This change was associated with a significant decrease in PMIR from 25.9% to 12.3% (p = 0.028), no longer different from the XT valve (12.2%). The PMIR after TAVR is higher with the S3 than with the XT and is independently associated with the implantation height. This increase in the PMIR may be avoided by intending an aortic stent extension >70%.

收起

展开

DOI:

10.1016/j.jcin.2015.12.023

被引量:

46

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(503)

参考文献(0)

引证文献(46)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读