Incidence and Potential Mechanism(s) of Post-Procedural Rise of Cardiac Biomarker in Patients With Coronary Artery Narrowing After Implantation of an Everolimus-Eluting Bioresorbable Vascular Scaffold or Everolimus-Eluting Metallic Stent.
摘要:
This study sought to evaluate the mechanism of post-procedural cardiac biomarker (CB) rise following device implantation. A fully bioresorbable Absorb scaffold, compared with everolimus-eluting metallic stents (EES), might be associated with a higher incidence of periprocedural myocardial injury. In 501 patients with stable or unstable angina randomized to either Absorb (335 patients) or EES (n = 166) in the ABSORB II trial, 3 types of CB (creatine kinase, creatine kinase-myocardial band, and troponin) were obtained before and after procedure. Per protocol, periprocedural myocardial infarction (PMI) was defined as creatine kinase rise >2× the upper limit of normal with creatine kinase-myocardial band rise. Incidence of side branch occlusion and any anatomic complications assessed by angiography was similar between the 2 treatment arms (side branch occlusion: Absorb: 5.3% vs. Xience: 7.6%, p = 0.07; any anatomic complication: Absorb: 16.4% vs. EES: 19.9%, p = 0.39). Fourteen patients who presented with recent myocardial infarction at entry with normalized creatine kinase-myocardial band according to the protocol were excluded for post-CB analysis. The overall compliance for CB was 97.8%. The CB rise subcategorized in 7 different ranges was comparable between the 2 treatment arms. PMI rate was numerically higher in the Absorb arm according to the per-protocol definitions, and treatment with overlapping devices was the only independent determinant of per-protocol PMI (odds ratio: 5.07, 95% confidence interval: 1.78 to 14.41, p = 0.002). There were no differences in the incidence of CB rise and PMI between Absorb and EES. Device overlap might be a precipitating factor of myocardial injury. (ABSORB II Randomized Clinical Trial: A Clinical Evaluation to Compare the Safety, Efficacy, and Performance of Absorb Everolimus Eluting Bioresorbable Vascular Scaffold System Against Xience Everolimus Eluting Coronary Stent System in the Treatment of Subjects With Ischemic Heart Disease Caused by De Novo Native Coronary Artery Lesions [ABSORB II]; NCT01425281).
收起
展开
DOI:
10.1016/j.jcin.2015.06.001
被引量:
年份:
2015


通过 文献互助 平台发起求助,成功后即可免费获取论文全文。
求助方法1:
知识发现用户
每天可免费求助50篇
求助方法1:
关注微信公众号
每天可免费求助2篇
求助方法2:
完成求助需要支付5财富值
您目前有 1000 财富值
相似文献(718)
参考文献(0)
引证文献(9)
来源期刊
影响因子:暂无数据
JCR分区: 暂无
中科院分区:暂无