Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer.
To compare the dosimetric performance of 3 different treatment techniques: hybrid volumetric-modulated arc therapy (hybrid-VMAT), pure-VMAT, and fixed-field intensity-modulated radiation therapy (F-IMRT) for whole-breast irradiation of left-sided early breast cancer. The hybrid-VMAT treatment technique and 2 other treatment techniques—pure-VMAT and F-IMRT—were compared retrospectively in 10 patients with left-sided early breast cancer. The treatment plans of these patients were replanned using the same contours based on the original computed tomography (CT) data sets. Dosimetric parameters were calculated to evaluate plan quality. Total monitor units (MUs) and delivery time were also recorded and evaluated. The hybrid-VMAT plan generated the best results in dose coverage of the target and the dose uniformity inside the target (p < 0.0001 for conformal index [CI]; p = 0.0002 for homogeneity index [HI] of planning target volume [PTV](50.4 Gy) and p < 0.0001 for HI of PTV(62 Gy)). Volumes of ipsilateral lung irradiated to doses of 20 Gy (V(20 Gy)) and 5 Gy (V(5 Gy)) by the hybrid-VMAT plan were significantly less than those of the F-IMRT and the pure-VMAT plans. The volume of ipsilateral lung irradiated to a dose of 5 Gy was significantly less using the hybrid-VMAT plan than that using the F-IMRT or the pure-VMAT plan. The total mean MUs for the hybrid-VMAT plan were significantly less than those for the F-IMRT or the pure-VMAT plan. The mean machine delivery time was 3.23 ± 0.29 minutes for the hybrid-VMAT plans, which is longer than that for the pure-VMAT plans but shorter than that for the F-IMRT plans. The hybrid-VMAT plan is feasible for whole-breast irradiation of left-sided early breast cancer.
Lin JF
,Yeh DC
,Yeh HL
,Chang CF
,Lin JC
... -
《-》
Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for pancreatic malignancies.
Volumetric-modulated arc therapy (VMAT) has been previously evaluated for several tumor sites and has been shown to provide significant dosimetric and delivery benefits when compared with intensity-modulated radiation therapy (IMRT). To date, there have been no published full reports on the benefits of VMAT use in pancreatic patients compared with IMRT. Ten patients with pancreatic malignancies treated with either IMRT or VMAT were retrospectively identified. Both a double-arc VMAT and a 7-field IMRT plan were generated for each of the 10 patients using the same defined tumor volumes, organs at risk (OAR) volumes, dose, fractionation, and optimization constraints. The planning tumor volume (PTV) maximum dose (55.8 Gy vs. 54.4 Gy), PTV mean dose (53.9 Gy vs. 52.1 Gy), and conformality index (1.11 vs. 0.99) were statistically similar between the IMRT and VMAT plans, respectively. The VMAT plans had a statistically significant reduction in monitor units compared with the IMRT plans (1109 vs. 498, p < 0.001). In addition, the doses to the liver, small bowel, and spinal cord were comparable between the IMRT and VMAT plans. However, the VMAT plans demonstrated a statistically significant reduction in the mean left kidney V(25) (9.4 Gy vs. 2.3 Gy, p = 0.018), mean right kidney V(15) (53.4 Gy vs. 45.9 Gy, p = 0.035), V(20) (32.2 Gy vs. 25.5 Gy, p = 0.016), and V(25) (21.7 Gy vs. 14.9 Gy, p = 0.001). VMAT was investigated in patients with pancreatic malignancies and compared with the current standard of IMRT. VMAT was found to have similar or improved dosimetric parameters for all endpoints considered. Specifically, VMAT provided reduced monitor units and improved bilateral kidney normal tissue dose. The clinical relevance of these benefits in the context of pancreatic cancer patients, however, is currently unclear and requires further investigation.
Ali AN
,Dhabaan AH
,Jarrio CS
,Siddiqi AK
,Landry JC
... -
《-》
Locoregional irradiation including internal mammary nodal region for left-sided breast cancer after breast conserving surgery: Dosimetric evaluation of 4 techniques.
The present study aimed to compare 4 techniques in the planning of locoregional irradiation including internal mammary nodal region for left-sided breast cancer. Ten patients with left-sided breast cancer undergoing breast conservation surgery were enrolled. For each patient, 4 treatment plans were performed: a helical tomotherapy (HT) plan, a volumetric modulated arc therapy (VMAT) plan, a static intensity modulated radiation therapy (IMRT) plan, and a hybrid IMRT plan, designed to encompass the whole breast, internal mammary, and supraclavicular nodal regions. The prescribed dose of radiation was 50 Gy in 25 fractions. The dosimetric parameters of the target and organs at risk, as well as the dose delivery time, were evaluated and compared using an independent-samples t-test. The HT and VMAT plans had the best conformity and homogeneity. For the HT, VMAT, IMRT, and hybrid IMRT plans, the mean conformity index (CI) and homogeneity index (HI) were 0.83, 0.82, 0.8, and 0.77 (p < 0.001); and 1.07, 1.11, 1.14, and 1.14 (p < 0.001), respectively. The corresponding V55 values were 0.3%, 11.4%, 27.02%, and 23.29% (p < 0.001). The Dmean and V20 of the left lung obtained using the HT plan were significantly lower than those of VMAT, IMRT, and hybrid IMRT plans (p = 0.002, p = 0.004). There were no significant differences in D max of LAD descending coronary artery, or the Dmean of the heart among the 4 types of plans. The HT and VMAT plans had a lower dose to other organ at risk (OARs) compared with the IMRT and hybrid IMRT plans. The mean delivery times were 1042 ± 33 seconds, 136 ± 12 seconds, 450 ± 65 seconds, and 451 ± 70 seconds for the HT, VMAT, IMRT, and hybrid IMRT plans, respectively (p < 0.001). For whole breast plus supraclavicular and internal mammary nodal irradiation in left-sided breast cancer, the VMAT technique is recommended considering both the dose distribution and the delivery time. Under circumstances in which dose distribution is a priority, the HT technique is a valid option.
Xu Y
,Wang J
,Hu Z
,Tian Y
,Ma P
,Li S
,Dai J
,Wang S
... -
《-》