Three-year patient-related and stent-related outcomes of second-generation everolimus-eluting Xience V stents versus zotarolimus-eluting resolute stents in real-world practice (from the Multicenter Prospective EXCELLENT and RESOLUTE-Korea Registries).
Long-term outcomes are imperative to confirm safety of drug-eluting stents. There have been 2 randomized controlled trials comparing everolimus-eluting stents (EESs) and Resolute zotarolimus-eluting stents (ZES-Rs). To date, long-term clinical outcomes of these stents were limited to only 1 report, which has recently reported 4-year comparisons of these stents. Therefore, more evidence is needed regarding long-term clinical outcomes of the second-generation stents. This study compared the long-term clinical outcomes of EES with ZES-R in "all-comer" cohorts up to 3-year follow-up. The EXCELLENT and RESOLUTE-Korea registries prospectively enrolled 3,056 patients treated with EES and 1,998 with ZES-R, respectively, without exclusions. Stent-related composite outcomes (target lesion failure) and patient-related composite events up to 3-year follow-up were compared in crude and propensity score-matched analyses. Of 5,054 patients, 3,830 patients (75.8%) had off-label indication (2,217 treated with EES and 1,613 treated with ZES-R). The stent-related outcome (189 [6.2%] vs 127 [6.4%], p = 0.812) and the patient-related outcome (420 [13.7%] vs 250 [12.5%], p = 0.581) did not differ between EES and ZES-R, respectively, at 3 years, which was corroborated by similar results from the propensity score-matched cohort (hazard ratio [HR] 0.92, 95% confidence interval [CI] 0.70 to 1.20, p = 0.523 and 0.85, 95% CI 0.70 to 1.02, p = 0.081, for stent- and patient-related outcomes, respectively). The rate of definite or probable stent thrombosis up to 3 years (22 [0.7%] vs 10 [0.5%], p = 0.370) was also similar. The rate of very late definite or probable stent thrombosis was very low and comparable between the 2 stents (3 [0.1%] vs 1 [0.1%], p = 0.657). In multivariate analysis, chronic renal failure (adjusted HR 3.615, 95% CI 2.440 to 5.354, p <0.001) and off-label indication (adjusted HR 1.782, 95% CI 1.169 to 2.718, p = 0.007) were the strongest predictors of target lesion failure at 3 years. In conclusion, both stents showed comparable safety and efficacy at 3-year follow-up in this robust real-world registry with unrestricted use of EES and ZES-R. Overall incidences of target lesion failure and definite stent thrombosis, including very late stent thrombosis, were low, even in the patients with off-label indications, suggesting excellent long-term safety and sustained efficacy of both types of second-generation drug-eluting stents.
Lee JM
,Park KW
,Han JK
,Yang HM
,Kang HJ
,Koo BK
,Bae JW
,Woo SI
,Park JS
,Jin DK
,Jeon DW
,Oh SK
,Park JS
,Kim DI
,Hyon MS
,Jeon HK
,Lim DS
,Kim MG
,Rha SW
,Her SH
,Hwang JY
,Kim S
,Choi YJ
,Kang JH
,Moon KW
,Jang Y
,Kim HS
... -
《-》
-
Safety and efficacy of second-generation everolimus-eluting Xience V stents versus zotarolimus-eluting resolute stents in real-world practice: patient-related and stent-related outcomes from the multicenter prospective EXCELLENT and RESOLUTE-Korea registr
This study sought to compare the safety and efficacy of the Xience V/Promus everolimus-eluting stent (EES) (Abbott Vascular, Temecula, California) with the Endeavor Resolute zotarolimus-eluting stent (ZES-R) (Medtronic Cardiovascular, Santa Rosa, California) in "all-comer" cohorts.
Only 2 randomized controlled trials have compared these stents.
The EXCELLENT (Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss After Stenting) and RESOLUTE-Korea registries prospectively enrolled 3,056 patients treated with the EES and 1,998 patients treated with the ZES-R, respectively, without exclusions. Stent-related composite outcomes (target lesion failure [TLF]) and patient-related composite outcomes were compared in crude and propensity score-matched analyses.
Of 5,054 patients, 3,830 (75.8%) had off-label indication (2,217 treated with EES and 1,613 treated with ZES-R). The stent-related outcome (82 [2.7%] vs. 58 [2.9%], p = 0.662) and the patient-related outcome (225 [7.4%] vs. 153 [7.7%], p = 0.702) did not differ between EES and ZES-R, respectively, at 1 year, which was corroborated by similar results from the propensity score-matched cohort. The rate of definite or probable stent thrombosis (18 [0.6%] vs. 7 [0.4%], p = 0.306) also was similar. In multivariate analysis, off-label indication was the strongest predictor of TLF (adjusted hazard ratio: 2.882; 95% confidence interval: 1.226 to 6.779; p = 0.015).
In this robust real-world registry with unrestricted use of EES and ZES-R, both stents showed comparable safety and efficacy at 1-year follow-up. Overall incidences of TLF and definite stent thrombosis were low, even in the patients with off-label indication, suggesting excellent safety and efficacy of both types of second-generation drug-eluting stents.
Park KW
,Lee JM
,Kang SH
,Ahn HS
,Yang HM
,Lee HY
,Kang HJ
,Koo BK
,Cho J
,Gwon HC
,Lee SY
,Chae IH
,Youn TJ
,Chae JK
,Han KR
,Yu CW
,Kim HS
... -
《-》
-
Everolimus-eluting Xience v/Promus versus zotarolimus-eluting resolute stents in patients with diabetes mellitus.
This study sought to compare everolimus-eluting stents (EES) versus Resolute zotarolimus-eluting stents (ZES) in terms of patient- or stent-related clinical outcomes in an "all-comer" group of patients with diabetes mellitus (DM) who underwent percutaneous coronary intervention.
DM significantly increases the risk of adverse events after percutaneous coronary intervention. The efficacy and safety of second-generation drug-eluting stents, in particular EES versus ZES, in patients with DM have not been extensively evaluated.
Patients with DM (1,855 of 5,054 patients, 36.7%) from 2 prospective registries (the EXCELLENT [Efficacy of Xience/Promus Versus Cypher in Reducing Late Loss After Stenting] registry and RESOLUTE-Korea [Registry to Evaluate the Efficacy of Zotarolimus-Eluting Stent]) who were treated with EES (n = 1,149) or ZES (n = 706) were compared. Stent-related outcome was target lesion failure (TLF), and patient-oriented composite events were a composite of all-cause mortality, any myocardial infarction, and any revascularization.
Despite a higher risk patient profile in the ZES group, both TLF (43 of 1,149 [3.7%] vs. 25 of 706 [3.5%], p = 0.899) and patient-oriented composite events (104 of 1,149 [9.1%] vs. 72 of 706 [10.2%], p = 0.416) were similar between the EES and ZES in patients with DM at 1 year. In those without DM, EES and ZES also showed comparable incidence of TLF (39 of 1,882 [2.1%] vs. 33 of 1,292 [2.6%], p = 0.370) and patient-oriented composite events (119 of 1,882 [6.3%] vs. 81 of 1,292 [6.3%], p = 0.951), which were all significantly lower than in the DM patients. These results were corroborated by similar findings from the propensity score-matched cohort. Upon multivariate analysis, chronic renal failure was the most powerful predictor of TLF in DM patients (hazard ratio: 4.39, 95% confidence interval: 1.91 to 10.09, p < 0.001).
After unrestricted use of second-generation drug-eluting stents in all-comers receiving percutaneous coronary intervention, both EES and ZES showed comparable clinical outcomes in the patients with DM up to 1 year of follow-up. DM compared with non-DM patients showed significantly worse patient- and stent-related outcomes. Nonetheless, overall incidences of TLF were low, even in the patients with DM, suggesting excellent safety and efficacy of both types of second-generation drug-eluting stents in this high-risk subgroup of patients.
Park KW
,Lee JM
,Kang SH
,Ahn HS
,Kang HJ
,Koo BK
,Rhew JY
,Hwang SH
,Lee SY
,Kang TS
,Kwak CH
,Hong BK
,Yu CW
,Seong IW
,Ahn T
,Lee HC
,Lim SW
,Kim HS
... -
《-》
-
4-year clinical outcomes and predictors of repeat revascularization in patients treated with new-generation drug-eluting stents: a report from the RESOLUTE All-Comers trial (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting
The aim of the study was to investigate 4-year outcomes and predictors of repeat revascularization in patients treated with the Resolute zotarolimus-eluting stent (R-ZES) (Medtronic, Minneapolis, Minnesota) and XIENCE V everolimus-eluting stent (EES) (Abbott Vascular, Abbott Park, Illinois) in the RESOLUTE (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention) All-Comers trial.
Data on long-term outcomes of new-generation drug-eluting stents are limited, and predictors of repeat revascularization due to restenosis and/or progression of disease are largely unknown.
Patients were randomly assigned to treatment with the R-ZES (n = 1,140) or the EES (n = 1,152). We assessed pre-specified safety and efficacy outcomes at 4 years including target lesion failure and stent thrombosis. Predictors of revascularization at 4 years were identified by Cox regression analysis.
At 4 years, the rates of target lesion failure (15.2% vs. 14.6%, p = 0.68), cardiac death (5.4% vs. 4.7%, p = 0.44), and target vessel myocardial infarction (5.3% vs. 5.4%, p = 1.00), clinically-indicated target lesion revascularization (TLR) (7.0% vs. 6.5%, p = 0.62), and definite/probable stent thrombosis (2.3% vs. 1.6%, p = 0.23) were similar with the R-ZES and EES. Independent predictors of TLR were age, insulin-treated diabetes, SYNTAX (Synergy between PCI with Taxus and Cardiac Surgery) score, treatment of saphenous vein grafts, ostial lesions, and in-stent restenosis. Independent predictors of any revascularization were age, diabetes, previous percutaneous coronary intervention, absence of ST-segment elevation myocardial infarction, smaller reference vessel diameter, SYNTAX score, and treatment of left anterior descending, right coronary artery, saphenous vein grafts, ostial lesions, or in-stent restenosis.
R-ZES and EES demonstrated similar safety and efficacy throughout 4 years. TLR represented less than one-half of all repeat revascularization procedures. Patient- and lesion-related factors predicting the risk of TLR and any revascularization showed considerable overlap. (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention [RESOLUTE-AC]; NCT00617084).
Taniwaki M
,Stefanini GG
,Silber S
,Richardt G
,Vranckx P
,Serruys PW
,Buszman PE
,Kelbaek H
,Windecker S
,RESOLUTE All-Comers Investigators
... -
《-》
-
A randomized controlled trial in second-generation zotarolimus-eluting Resolute stents versus everolimus-eluting Xience V stents in real-world patients: the TWENTE trial.
The aim of this study was to compare the safety and efficacy of Resolute zotarolimus-eluting stents (ZES) (Medtronic Cardiovascular, Santa Rosa, California) with Xience V everolimus-eluting stents (EES) (Abbott Vascular Devices, Santa Clara, California) at 1-year follow-up.
Only 1 randomized trial previously compared these stents.
This investigator-initiated, patient-blinded, randomized noninferiority study had limited exclusion criteria (acute ST-segment elevation myocardial infarctions not eligible). Patients (n = 1,391; 81.4% of eligible population) were randomly assigned to ZES (n = 697) or EES (n = 694). Liberal use of stent post-dilation was encouraged. Cardiac biomarkers were systematically assessed. The primary endpoint was target vessel failure (TVF), a composite of cardiac death, myocardial infarction not clearly attributable to non-target vessels, and clinically indicated target-vessel revascularization. An external independent research organization performed clinical event adjudication (100% follow-up data available). Analysis was by intention-to-treat.
Acute coronary syndromes were present in 52% and "off-label" feature in 77% of patients. Of the lesions, 70% were type B2/C; the post-dilation rate was very high (82%). In ZES and EES, TVF occurred in 8.2% and 8.1%, respectively (absolute risk-difference 0.1%; 95% confidence interval: -2.8% to 3.0%, p(noninferiority) = 0.001). There was no significant between-group difference in TVF components. The definite-or-probable stent thrombosis rates were relatively low and similar for ZES and EES (0.9% and 1.2%, respectively, p = 0.59). Definite stent thrombosis rates were also low (0.58% and 0%, respectively, p = 0.12). In EES, probable stent thrombosis beyond day 8 was observed only in patients not adhering to dual antiplatelet therapy.
Resolute ZES were noninferior to Xience V EES in treating "real-world" patients with a vast majority of complex lesions and "off-label" indications for drug-eluting stents, which were implanted with liberal use of post-dilation. (The Real-World Endeavor Resolute Versus XIENCE V Drug-Eluting SteNt Study: Head-to-head Comparison of Clinical Outcome After Implantation of Second Generation Drug-eluting Stents in a Real World Scenario; NCT01066650).