Minimizing ultraviolet noise due to mis-matches between detector flow cell and post column mobile phase temperatures in supercritical fluid chromatography: effect of flow cell design.

来自 PUBMED

作者:

Berger TA

展开

摘要:

A mis-match between the post-column mobile phase temperature and the UV detector flow cell temperature can cause significant UV noise in supercritical fluid chromatography (SFC). Deviations as little as 5 °C can increase noise as much as 5 times, making the detector unsuited for trace analysis. Two approaches were used to minimize this noise. When a flow cell was in direct thermal contact (metal on metal) with the detector optical bench, the mobile phase temperature was actively controlled to the measured flow cell temperature, by using one of the heat exchangers (HX) in the column compartment. However, with some older, but still widely used flow cell designs, this required repeated, hourly monitoring of the flow cell temperature and repeated manual adjustment of the heat exchanger temperature, due to thermal drift. Flow cell design had a strong influence on susceptibility to this thermally induced noise. Thermally insulating the flow cell from the optical bench made some cells much less susceptible to such thermally induced noise. Five different flow cells, some insulated, some un-insulated, were evaluated. Most had a truncated conical flow path, but one had a cylindrical flow path. Using either approach, the ASTM noise, with a 10mm, 13 μL conical flow cell, could be optimized to ≈0.007 mAU at 2.5 Hz, in SFC, which is very near the 0.006 mAU manufacturer's specification for HPLC. The insulated version of this flow cell required far less optimization, compared to the un-insulated version. At 150 bar, an experimental 3mm, 2 μL flow cell, with only one side insulated, yielded noise slightly too high (≈0.16-0.18 mAU) for trace analysis, at 80 Hz. However, at 200 bar, noise at 80 Hz was <0.06 mAU, which should allow quantification of a 1 mAU tall trace component with a signal to noise ratio (S/N) >10. Even partially un-insulated, this flow cell design was much less susceptible to thermally induced noise. Further insulating this flow cell design failed to improve performance.

收起

展开

DOI:

10.1016/j.chroma.2014.08.067

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(119)

参考文献(0)

引证文献(0)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读