Safety and effectiveness of the INCRAFT AAA Stent Graft for endovascular repair of abdominal aortic aneurysms.

来自 PUBMED

作者:

Torsello GScheinert DBrunkwall JSChiesa RCoppi GPratesi C

展开

摘要:

This study evaluated the 2-year safety and effectiveness of the European First-in-Human INNOVATION trial for the INCRAFT AAA Stent Graft system (Cordis Corp, Bridgewater, NJ), an ultra-low-profile device for the treatment of abdominal aortic aneurysms. From March 2010 to June 2011, the INNOVATION prospective multicenter trial involving six centers in Europe enrolled and treated 60 asymptomatic patients (95% male; mean age, 74.4 ± 6.9 years) with the INCRAFT System. Main inclusion criteria included proximal aortic neck length of 15 mm or more with a diameter up to 27 mm; distal iliac landing zones with a length greater than 10 mm and a diameter between 9 and 18 mm; and aortic bifurcation >18 mm in diameter and access vessels large enough to accept the 14F outer diameter of the delivery system. The primary end point was technical success at 1 month; 2-year safety end points included the absence of device- or procedure-related major adverse events, absence of type I or III endoleaks, and maintenance of device integrity through 2 years of follow-up. Study oversight was provided by a Data Safety Monitoring Board with event adjudication by a Clinical Events Committee and imaging analysis by an independent core laboratory. Of 60 successfully treated patients, two did not come back for their 1-month evaluation but remained enrolled in the study; 56 were evaluated at 1 year and 52 at 2 years. Of the 58 patients, 56 met the 1-month primary safety and effectiveness end point (97%; 95% confidence interval, 88%-100%). All patients were free from aneurysm enlargement through 2 years. There were no type I or III endoleaks at the 2-year time point. All-cause mortality at 2 years was 11.5%, and no death was device or procedure related. In total, three patients required a postprocedure intervention, two to repair a type I endoleak and one for limb occlusion. Core laboratory evaluation of the postoperative imaging studies documented absence of endograft migration and stent fractures in all patients. The INCRAFT AAA Stent Graft System provides a durable solution for patients with abdominal aortic aneurysms, with a low frequency of device-related events through 2 years of follow-up.

收起

展开

DOI:

10.1016/j.jvs.2014.06.007

被引量:

2

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(509)

参考文献(0)

引证文献(2)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读