-
Fetal head-symphysis distance and mode of delivery in the second stage of labor.
To evaluate whether the fetal head-symphysis distance measured by three-dimensional transperineal ultrasound during the active second stage predicts operative delivery.
Prospective observational study.
University hospital, Bologna, Italy.
Seventy-one nulliparous women at term in active second stage of labor.
We acquired a series of sonographic volumes at the beginning of the active second stage (T1) and every 20 min thereafter (T2, T3, T4, T5, T6) until delivery. All volumes were retrospectively analyzed and head-symphysis distance was measured for each acquisition. We compared head-symphysis distance between women with spontaneous vaginal delivery and those with operative delivery. Receiver operator characteristic curves were constructed to estimate the accuracy of head-symphysis distance in the prediction of operative delivery. Logistic regression was used to identify independent variables associated with operative delivery.
Operative delivery (vacuum or cesarean).
Of the women included, 81.7% had a spontaneous vaginal delivery and 18.3% underwent operative delivery. Women with spontaneous vaginal delivery had shorter head-symphysis distance than women in the operative delivery group at T1 (p < 0.001), T2 (p < 0.001) and T3 (p = 0.025), whereas no significant differences were recorded thereafter. Receiver operator characteristic curves revealed accuracy values of 81.0%, 87.9% and 77.6% in the prediction of operative delivery at T1, T2 and T3, respectively. At multivariate logistic regression head-symphysis distance and epidural analgesia were the only independent predictors of operative delivery among ultrasonographic, maternal and intrapartum variables.
Ultrasonographic measurement of head-symphysis distance in the second stage of labor can be used to predict operative delivery.
Youssef A
,Maroni E
,Cariello L
,Bellussi F
,Montaguti E
,Salsi G
,Morselli-Labate AM
,Paccapelo A
,Rizzo N
,Pilu G
,Ghi T
... -
《-》
-
Sonographic pattern of fetal head descent: relationship with duration of active second stage of labor and occiput position at delivery.
The objectives of this study were firstly to assess the longitudinal changes of various sonographic parameters of fetal head progression in relation to length of active second stage of labor, and secondly to compare ultrasound findings obtained longitudinally among fetuses with persistent occiput posterior (OP) vs those with persistent occiput anterior (OA) position.
From a series of nulliparous low-risk women at term attending the labor ward of our university hospital, transperineal ultrasound volumes were prospectively acquired at the beginning of the active second stage (T1) and at 40-min intervals thereafter until delivery (T2, T3). Sonographic parameters were derived from offline analysis of each volume, including the angle of progression (AoP), progression distance (PD), head-symphysis distance (HSD), head direction (HD) and midline angle. These parameters were compared between patients who delivered within 60 min from the beginning of the active second stage of labor (early delivery) and those who remained undelivered by that time (late delivery). Fetal head position was determined from stored digital images of transabdominal examinations performed at the beginning of the active second stage. Comparison was performed between fetuses with OA and those with persistent OP position at delivery.
Spontaneous vaginal delivery was achieved in 58 (81.7%) cases, whereas vacuum extraction and Cesarean section were performed in eight (11.3%) and five (7.0%) cases, respectively. Delivery was achieved within 60 min from the beginning of the active second stage in 44 (62.0%) patients. In the early vs late delivery groups, measurements of AoP, HSD and PD at T1 were significantly different (AoP, 143.9 ± 20.5° vs 125.3 ± 15.0°, P < 0.001; HSD, 14.8 ± 4.5 mm vs 20.9 ± 5.8 mm, P < 0.001; PD, 44.0 ± 14.1 vs 35.0 ± 13.1 mm, P = 0.008). On logistic regression analysis of data obtained at T1, maternal body mass index, oxytocin administration, neonatal birth weight and HSD appeared to predict independently duration of the active second stage. Among fetuses delivering in the OP position (n = 10, 13.5%), Cesarean delivery was significantly more common than in those delivering in the OA position (n = 5 (50.0%) vs n = 2 (3.1%), P = 0.001). Women with persistent OP position compared with OA showed a significantly different AoP at T1 (122 ± 17° vs 138 ± 20°, P = 0.016), HD and HSD at T1 (HD, 112 ± 17 mm vs 86 ± 19 mm, P < 0.001; HSD, 16.5 ± 5.4 mm vs 22.8 ± 6.6 mm, P = 0.008) and at T2 (HD, 120 ± 16 vs 82 ± 27 mm, P = 0.008; HSD, 12.6 ± 3.4 mm vs 18.5 ± 5.4 mm, P = 0.038).
AoP, PD and HSD are significantly different between patients undergoing delivery before or after 60 min from the beginning of the active second stage of labor. Ultrasound parameters are among the significant predictors of duration of the active second stage. Moreover, in fetuses persisting in the OP position vs those delivering in the OA position, fetal head progression seems to differ at early phases of the active second stage.
Ghi T
,Maroni E
,Youssef A
,Morselli-Labate AM
,Paccapelo A
,Montaguti E
,Rizzo N
,Pilu G
... -
《-》
-
Prediction of spontaneous vaginal delivery in nulliparous women with a prolonged second stage of labor: the value of intrapartum ultrasound.
A limited number of studies have addressed the role of intrapartum ultrasound in the prediction of the mode of delivery in women with prolonged second stage of labor.
The objective of the study was to evaluate the role of transabdominal and transperineal sonographic findings in the prediction of spontaneous vaginal delivery among nulliparous women with prolonged second stage of labor.
This was a 2-center prospective study conducted at 2 tertiary maternity units. Nulliparous women with a prolonged active second stage of labor, as defined by active pushing lasting more than 120 minutes, were eligible for inclusion. Transabdominal ultrasound to evaluate the fetal head position and transperineal ultrasound for the measurement of the midline angle, the head-perineum distance, and the head-symphysis distance were performed in between uterine contractions and maternal pushes. At transperineal ultrasound the angle of progression was measured at rest and at the peak of maternal pushing effort. The delta angle of progression was defined as the difference between the angle of progression measured during active pushing at the peak of maternal effort and the angle of progression at rest. The sonographic findings of women who had spontaneous vaginal delivery vs those who required obstetric intervention, either vacuum extraction or cesarean delivery, were evaluated and compared.
Overall, 109 were women included. Spontaneous vaginal delivery and obstetric intervention were recorded in 40 (36.7%) and 69 (63.3%) patients, respectively. Spontaneous vaginal delivery was associated with a higher rate of occiput anterior position (90% vs 53.2%, P < .0001), lower head-perineum distance and head-symphysis distance (33.2 ± 7.8 mm vs 40.1 ± 9.5 mm, P = .001, and 13.1 ± 4.6 mm vs 19.5 ± 8.4 mm, P < .001, respectively), narrower midline angle (29.6° ± 15.3° vs 54.2° ± 23.6°, P < .001) and wider angle of progression at the acme of the pushing effort (153.3° ± 19.8° vs 141.8° ± 25.7°, P = .02) and delta-angle of progression (17.3° ± 12.9° vs 12.5° ± 11.0°, P = .04). At logistic regression analysis, only the midline angle and the head-symphysis distance proved to be independent predictors of spontaneous vaginal delivery. More specifically, the area under the curve for the prediction of spontaneous vaginal delivery was 0.80, 95% confidence interval (0.69-0.92), P < .001, and 0.74, 95% confidence interval (0.65-0.83), P = .002, for the midline angle and for the head-symphysis distance, respectively.
Transabdominal and transperineal intrapartum ultrasound parameters can predict the likelihood of spontaneous vaginal delivery in nulliparous women with prolonged second stage of labor.
Dall'Asta A
,Angeli L
,Masturzo B
,Volpe N
,Schera GBL
,Di Pasquo E
,Girlando F
,Attini R
,Menato G
,Frusca T
,Ghi T
... -
《-》
-
Intrapartum transperineal ultrasound assessment of fetal head progression in active second stage of labor and mode of delivery.
To compare longitudinal changes in angle of progression (AoP) and midline angle (MLA) during the active second stage of labor according to the mode of delivery.
A three-dimensional transperineal ultrasound volume was acquired in a series of nulliparous women at the beginning of the active second stage (T1) and every 20 min thereafter (T2, T3, T4, T5 and T6). Following delivery, all ultrasound volumes were analyzed and AoP and MLA were measured.
Among 71 women included in the study, 58 underwent spontaneous vaginal delivery (group A) and 13 underwent operative delivery (group B) (eight by vacuum extraction and five by Cesarean section). When compared with Group B, Group A had a wider AoP only at T1 (140.0 ± 20.2° vs. 122.9 ± 16.7°; P = 0.010) and T2 (149.7 ± 20.7° vs. 126.9 ± 17.5°; P = 0.006). MLA was narrower in group A only at T3 (21.2 ± 11.7° vs. 40.8 ± 27.9°; P = 0.043), T4 (18.2 ± 15.0° vs. 47.4 ± 29.6°; P = 0.020) and T5 (18.3 ± 6.0° vs. 34.7 ± 4.2°; P = 0.034). On stepwise forward multiple logistic regression analysis, both AoP and MLA were independently associated with operative delivery (OR = 0.955 and OR = 1.018, respectively).
Ultrasonographic assessment of fetal head descent in the second stage of labor may play a role in the prediction of the mode of delivery.
Ghi T
,Youssef A
,Maroni E
,Arcangeli T
,De Musso F
,Bellussi F
,Nanni M
,Giorgetta F
,Morselli-Labate AM
,Iammarino MT
,Paccapelo A
,Cariello L
,Rizzo N
,Pilu G
... -
《-》
-
Sonographic prediction of outcome of vacuum deliveries: a multicenter, prospective cohort study.
Safe management of the second stage of labor is of great importance. Unnecessary interventions should be avoided and correct timing of interventions should be focused. Ultrasound assessment of fetal position and station has a potential to improve the precision in diagnosing and managing prolonged or arrested labors. The decision to perform vacuum delivery is traditionally based on subjective assessment by digital vaginal examination and clinical expertise and there is currently no method of objectively quantifying the likelihood of successful delivery. Prolonged attempts at vacuum delivery are associated with neonatal morbidity and maternal trauma, especially so if the procedure is unsuccessful and a cesarean is performed.
The aim of the study was to assess if ultrasound measurements of fetal position and station can predict duration of vacuum extractions, mode of delivery, and fetal outcome in nulliparous women with prolonged second stage of labor.
We performed a prospective cohort study in nulliparous women at term with prolonged second stage of labor in 7 European maternity units from 2013 through 2016. Fetal head position and station were determined using transabdominal and transperineal ultrasound, respectively. Our preliminary clinical experience assessing head-perineum distance prior to vacuum delivery suggested that we should set 25 mm for the power calculation, a level corresponding roughly to +2 below the ischial spines. The main outcome was duration of vacuum extraction in relation to ultrasound measured head-perineum distance with a predefined cut-off of 25 mm, and 220 women were needed to discriminate between groups using a hazard ratio of 1.5 with 80% power and alpha 5%. Secondary outcomes were delivery mode and umbilical artery cord blood samples after birth. The time interval was evaluated using survival analyses, and the outcomes of delivery were evaluated using receiver operating characteristic curves and descriptive statistics. Results were analyzed according to intention to treat.
The study population comprised 222 women. The duration of vacuum extraction was shorter in women with head-perineum distance ≤25 mm (log rank test <0.01). The estimated median duration in women with head-perineum distance ≤25 mm was 6.0 (95% confidence interval, 5.2-6.8) minutes vs 8.0 (95% confidence interval, 7.1-8.9) minutes in women with head-perineum distance >25 mm. The head-perineum distance was associated with spontaneous delivery with area under the curve 83% (95% confidence interval, 77-89%) and associated with cesarean with area under the curve 83% (95% confidence interval, 74-92%). In women with head-perineum distance ≤35 mm, 7/181 (3.9%) were delivered by cesarean vs 9/41 (22.0%) in women with head-perineum distance >35 mm (P <.01). Ultrasound-assessed position was occiput anterior in 73%. Only 3/138 (2.2%) fetuses in occiput anterior position and head-perineum distance ≤35 mm vs 6/17 (35.3%) with nonocciput anterior position and head-perineum distance >35 mm were delivered by cesarean. Umbilical cord arterial pH <7.10 occurred in 2/144 (1.4%) women with head-perineum distance ≤35 mm compared to 8/40 (20.0%) with head-perineum distance >35 mm (P < .01).
Ultrasound has the potential to predict labor outcome in women with prolonged second stage of labor. The information obtained could guide whether vacuum delivery should be attempted or if cesarean is preferable, whether senior staff should be in attendance, and if the vacuum attempt should be performed in the operating theater.
Kahrs BH
,Usman S
,Ghi T
,Youssef A
,Torkildsen EA
,Lindtjørn E
,Østborg TB
,Benediktsdottir S
,Brooks L
,Harmsen L
,Romundstad PR
,Salvesen KÅ
,Lees CC
,Eggebø TM
... -
《-》