Comparison of Xpert MTB/RIF with line probe assay for detection of rifampin-monoresistant Mycobacterium tuberculosis.
The MTBDRplus line probe assay (LPA) and Xpert MTB/RIF have been endorsed by the World Health Organization for the rapid diagnosis of drug-resistant tuberculosis. However, there is no clarity regarding the superiority of one over the other. In a double-blinded prospective study, we evaluated the efficacy of the Xpert MTB/RIF on samples that were first tested by LPA under the revised national tuberculosis control program of India. A total of 405 sputum samples from suspected drug-resistant tuberculosis patients were included. Of these, 285 smear-positive samples were subjected to LPA. Seventy-two (25.8%) samples showed multidrug resistance, 62 (22.2%) showed rifampin monoresistance, 29 (10.3%) showed isoniazid monoresistance, and 116 (41.5%) were pan-susceptible. Six (2.1%) of the samples gave invalid results. Of the 62 rifampin-monoresistant samples by LPA, 38 (61.4%) showed rifampin resistance, while 21 (33.8%) were found susceptible to rifampin by Xpert MTB/RIF using cartridge version G4. Three (4.8%) samples gave an error. Of the 116 pan-susceptible samples, only 83 were available for Xpert MTB/RIF testing; 4 (5.1%) were rifampin resistant, 74 (94.8%) were susceptible, and 5 (6.0%) showed an error. The 25 discrepant samples were further subjected to MGIT960 drug susceptibility testing. The MGIT960 results showed 100% agreement with LPA results but only 64.4% agreement with Xpert MTB/RIF results. Sequencing analysis of discrepant samples showed 91.3% concordance with LPA but only 8.7% concordance with the Xpert MTB/RIF assay. These findings indicate that by using Xpert MTB/RIF testing we might be underestimating the burden of drug-resistant tuberculosis and indicate that country-specific probes need to be designed to increase the sensitivity of the Xpert MTB/RIF.
Rufai SB
,Kumar P
,Singh A
,Prajapati S
,Balooni V
,Singh S
... -
《-》
Xpert MTB/RIF Ultra for detection of Mycobacterium tuberculosis and rifampicin resistance: a prospective multicentre diagnostic accuracy study.
The Xpert MTB/RIF assay is an automated molecular test that has improved the detection of tuberculosis and rifampicin resistance, but its sensitivity is inadequate in patients with paucibacillary disease or HIV. Xpert MTB/RIF Ultra (Xpert Ultra) was developed to overcome this limitation. We compared the diagnostic performance of Xpert Ultra with that of Xpert for detection of tuberculosis and rifampicin resistance.
In this prospective, multicentre, diagnostic accuracy study, we recruited adults with pulmonary tuberculosis symptoms presenting at primary health-care centres and hospitals in eight countries (South Africa, Uganda, Kenya, India, China, Georgia, Belarus, and Brazil). Participants were allocated to the case detection group if no drugs had been taken for tuberculosis in the past 6 months or to the multidrug-resistance risk group if drugs for tuberculosis had been taken in the past 6 months, but drug resistance was suspected. Demographic information, medical history, chest imaging results, and HIV test results were recorded at enrolment, and each participant gave at least three sputum specimen on 2 separate days. Xpert and Xpert Ultra diagnostic performance in the same sputum specimen was compared with culture tests and drug susceptibility testing as reference standards. The primary objectives were to estimate and compare the sensitivity of Xpert Ultra test with that of Xpert for detection of smear-negative tuberculosis and rifampicin resistance and to estimate and compare Xpert Ultra and Xpert specificities for detection of rifampicin resistance. Study participants in the case detection group were included in all analyses, whereas participants in the multidrug-resistance risk group were only included in analyses of rifampicin-resistance detection.
Between Feb 18, and Dec 24, 2016, we enrolled 2368 participants for sputum sampling. 248 participants were excluded from the analysis, and 1753 participants were distributed to the case detection group (n=1439) and the multidrug-resistance risk group (n=314). Sensitivities of Xpert Ultra and Xpert were 63% and 46%, respectively, for the 137 participants with smear-negative and culture-positive sputum (difference of 17%, 95% CI 10 to 24); 90% and 77%, respectively, for the 115 HIV-positive participants with culture-positive sputum (13%, 6·4 to 21); and 88% and 83%, respectively, across all 462 participants with culture-positive sputum (5·4%, 3·3 to 8·0). Specificities of Xpert Ultra and Xpert for case detection were 96% and 98% (-2·7%, -3·9 to -1·7) overall, and 93% and 98% for patients with a history of tuberculosis. Xpert Ultra and Xpert performed similarly in detecting rifampicin resistance.
For tuberculosis case detection, sensitivity of Xpert Ultra was superior to that of Xpert in patients with paucibacillary disease and in patients with HIV. However, this increase in sensitivity came at the expense of a decrease in specificity.
Government of Netherlands, Government of Australia, Bill & Melinda Gates Foundation, Government of the UK, and the National Institute of Allergy and Infectious Diseases.
Dorman SE
,Schumacher SG
,Alland D
,Nabeta P
,Armstrong DT
,King B
,Hall SL
,Chakravorty S
,Cirillo DM
,Tukvadze N
,Bablishvili N
,Stevens W
,Scott L
,Rodrigues C
,Kazi MI
,Joloba M
,Nakiyingi L
,Nicol MP
,Ghebrekristos Y
,Anyango I
,Murithi W
,Dietze R
,Lyrio Peres R
,Skrahina A
,Auchynka V
,Chopra KK
,Hanif M
,Liu X
,Yuan X
,Boehme CC
,Ellner JJ
,Denkinger CM
,study team
... -
《-》