A clinical and angiographic study of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with multivessel coronary artery disease: the EXECUTIVE trial (EXecutive RCT: evaluating XIENCE V in a multi vessel disease).
This study sought to investigate the efficacy and performance of the XIENCE V everolimus-eluting stent (EES) (Abbott Vascular, Santa Clara, California) in the treatment of de novo coronary lesions in patients with 2- to 3-vessel multivessel coronary artery disease (MV-CAD).
Drug-eluting stents (DES) have emerged as an alternative to conventional coronary artery bypass surgery in patients with MV-CAD although first-generation DES yielded inferior efficacy and safety compared with surgery.
Prospective, randomized (1:1), multicenter feasibility trial was designed to assess angiographic efficacy of EES compared with the TAXUS paclitaxel-eluting stent (PES) in 200 patients, and a prospective, open-label, single-arm, controlled registry was designed to analyze the clinical outcome of EES at 1-year follow-up in 400 MV-CAD patients. For the randomized trial, the primary endpoint was in-stent late loss at 9 months. For the registry, the primary endpoint was a composite of all-cause death, myocardial infarction, and ischemia-driven target vessel revascularization at 12 months.
The primary endpoint per single lesion was significantly lower in the EES group compared with the PES group (-0.03 ± 0.49 mm vs. 0.23 ± 0.51 mm, p = 0.001). Similar results were observed when analyzing all lesions (0.05 ± 0.51 mm vs. 0.24 ± 0.50 mm, p < 0.001). Clinical outcome at 1 year yielded a composite of major adverse cardiac events of 9.2% in the single-arm registry, and 11.1% and 16.5% in the EES and PES randomized groups, respectively (p = 0.30).
The EXECUTIVE trial was a randomized pilot trial dedicated to the comparison of the efficacy of 2 different DES among patients with 2- to 3-vessel MV-CAD. The study shows lower in-stent late loss at 9 months with the EES XIENCE V compared with the PES TAXUS Libertè, and a low major adverse cardiac event rate at 1 year in patients with 2-to 3-vessel MV-CAD. (EXECUTIVE [EXecutive RCT: Evaluating XIENCE V in a Multi Vessel Disease]; NCT00531011).
Ribichini F
,Romano M
,Rosiello R
,La Vecchia L
,Cabianca E
,Caramanno G
,Milazzo D
,Loschiavo P
,Rigattieri S
,Musarò S
,Pironi B
,Fiscella A
,Amico F
,Indolfi C
,Spaccarotella C
,Bartorelli A
,Trabattoni D
,Della Rovere F
,Rolandi A
,Beqaraj F
,Belli R
,Sangiorgio P
,Villani R
,Berni A
,Sheiban I
,Lopera Quijada MJ
,Cappi B
,Ribaldi L
,Vassanelli C
,EXECUTIVE Trial Investigators
... -
《-》
-
5-year results of a randomized comparison of XIENCE V everolimus-eluting and TAXUS paclitaxel-eluting stents: final results from the SPIRIT III trial (clinical evaluation of the XIENCE V everolimus eluting coronary stent system in the treatment of patient
This study sought to evaluate the long-term safety and efficacy of everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES) in patients with obstructive coronary artery disease.
The use of EES compared to PES has been shown to result in improved clinical outcomes in patients undergoing PCI. However, there have been concerns regarding the durability of these benefits over longer-term follow-up.
SPIRIT III was a prospective, multicenter trial in which 1,002 patients were randomized 2:1 to EES versus PES. Endpoints included ischemia-driven target vessel failure (TVF) (death, myocardial infarction (MI), or ischemia-driven target vessel revascularization [TVR]), the pre-specified primary endpoint), target lesion failure (TLF) (cardiac death, target-vessel MI, or ischemia-driven target lesion revascularization [TLR]), major adverse cardiac events (MACE) (cardiac death, MI, or ischemia-driven TLR), their individual components and stent thrombosis.
Five-year follow-up was available in 91.9% of patients. Treatment with EES versus PES resulted in lower 5-year Kaplan-Meier rates of TVF (19.3% vs. 24.5%, p = 0.05), TLF (12.7% vs. 19.0%, p = 0.008), and MACE (13.2% vs. 20.7%, p = 0.007). EES also resulted in reduced rates of all-cause death (5.9% vs. 10.1%, p = 0.02), with nonsignificantly different rates of MI, stent thrombosis, and TLR, and no evidence of late catch-up of TLR over time.
At 5 years after treatment, EES compared to PES resulted in durable benefits in composite safety and efficacy measures as well as all-cause mortality. Additionally, the absolute difference in TLR between devices remained stable over time without deterioration of effect during late follow-up.
Gada H
,Kirtane AJ
,Newman W
,Sanz M
,Hermiller JB
,Mahaffey KW
,Cutlip DE
,Sudhir K
,Hou L
,Koo K
,Stone GW
... -
《-》
-
Meta-analysis of everolimus-eluting versus paclitaxel-eluting stents in coronary artery disease: final 3-year results of the SPIRIT clinical trials program (Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of P
This study sought to investigate whether the everolimus-eluting stent (EES) is superior to the paclitaxel-eluting stent (PES) with respect to long-term individual clinical outcomes.
Individual studies have indicated a clinical advantage of coronary EES compared with PES with respect to restenosis and the composite endpoint of major adverse cardiac events. However, these trials were not powered for superiority in low-frequency event rates and have reported limited data beyond 1-year follow-up.
We conducted a meta-analysis of the final 3-year results from the international SPIRIT (Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) II, III, and IV clinical trials. Individual patient data from 4,989 patients who were prospectively randomized to treatment with EES (n = 3,350) or PES (n = 1,639) were pooled for analysis.
At 3-year follow-up, EES was superior to PES in reducing the following event rates: target lesion failure (8.9% vs. 12.5%, hazard ratio [HR]: 0.71, 95% confidence interval [CI]: 0.59 to 0.85; p = 0.0002), all-cause mortality (3.2% vs 5.1%, HR: 0.65, 95% CI: 0.49 to 0.86; p = 0.003), myocardial infarction (3.2% vs. 5.1%, HR: 0.64, 95% CI: 0.48 to 0.85; p = 0.002), cardiac death or myocardial infarction (4.4% vs. 6.3%, HR: 0.70, 95% CI: 0.54 to 0.90; p = 0.005), ischemia-driven target lesion revascularization (6.0% vs. 8.2%, HR: 0.72, 95% CI: 0.58 to 0.90; p = 0.004), stent thrombosis (0.7% vs. 1.7%, HR: 0.45, 95% CI: 0.26 to 0.78; p = 0.003), and major adverse cardiac events (9.4% vs. 13.0%, HR: 0.71, 95% CI: 0.60 to 0.85; p = 0.0002). No interaction was present between stent type and the 3-year relative rates of target lesion failure across a broad range of subgroups, with the exception of diabetes and vessel (left anterior descending vs. other).
In this large dataset with 3-year follow-up, coronary implantation of EES compared with PES resulted in reduced rates of all-cause mortality, myocardial infarction, ischemia-driven target lesion revascularization, stent thrombosis, and target lesion failure. Further research is warranted to characterize possible interactions between stent type, diabetes, and vessel.
Dangas GD
,Serruys PW
,Kereiakes DJ
,Hermiller J
,Rizvi A
,Newman W
,Sudhir K
,Smith RS Jr
,Cao S
,Theodoropoulos K
,Cutlip DE
,Lansky AJ
,Stone GW
... -
《-》
-
3-year clinical follow-up of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with de novo coronary artery lesions: the SPIRIT II trial (Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the
Garg S
,Serruys P
,Onuma Y
,Dorange C
,Veldhof S
,Miquel-Hébert K
,Sudhir K
,Boland J
,Huber K
,Garcia E
,te Riele JA
,SPIRIT II Investigators
... -
《-》
-
Impact of lesion length and vessel size on clinical outcomes after percutaneous coronary intervention with everolimus- versus paclitaxel-eluting stents pooled analysis from the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent
The aim of this study was to investigate the impact of reference vessel diameter (RVD) and lesion length (LL) on the relative safety and efficacy of everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES).
Lesion length and RVD are well-known predictors of adverse events after percutaneous coronary intervention.
Patient-level data were pooled from the randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) trials. Quantitative angiographic core laboratory data were available for 6,183 patients randomized to EES (n = 3,944) or PES (n = 2,239). Long lesions and small vessels were defined as LL >median (13.4 mm) and RVD ≤median (2.65 mm), respectively. Major adverse cardiac events (MACE) (consisting of cardiac death, myocardial infarction, or ischemia-driven target lesion revascularization) were assessed at 2 years, according to stent type in 3 groups: short lesions in large vessels (group A, n = 1,297); long lesions or small vessels but not both (group B, n = 2,981); and long lesions in small vessels (group C, n = 1,905).
The pooled 2-year MACE rates were 5.6%, 8.2%, and 10.4% in Groups A, B, and C, respectively (p < 0.0001). There was no significant interaction between lesion group and stent type (p = 0.64), indicating lower MACE with EES compared with PES regardless of LL and RVD. However, the absolute difference was largest in Groups B and C. In Group A, 2-year MACE rates were not significantly different between EES and PES (4.8% vs. 7.0%, respectively, p = 0.11). In contrast, EES was associated with lower 2-year rates of MACE in Group B (6.6% vs. 11.2%, p < 0.01) and in Group C (9.1% vs. 12.7%, p = 0.008) as well as lower rates of myocardial infarction, target lesion revascularization, and stent thrombosis. Multivariable analysis confirmed EES versus PES as an independent predictor of freedom from MACE in Groups B and C.
Patients with short lesions in large vessels have low rates of MACE at 2 years after treatment with either EES or PES. In higher-risk patients with long lesions and/or small vessels, EES results in significant improvements in both clinical safety and efficacy outcomes. (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT00180479; SPIRIT IV Clinical Trial: Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT00307047; A Randomized Controlled Trial of Everolimus-eluting Stents and Paclitaxel-eluting Stents for Coronary Revascularization in Daily Practice: The COMPARE Trial; NCT01016041).
Claessen BE
,Smits PC
,Kereiakes DJ
,Parise H
,Fahy M
,Kedhi E
,Serruys PW
,Lansky AJ
,Cristea E
,Sudhir K
,Sood P
,Simonton CA
,Stone GW
... -
《-》