Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve.

来自 PUBMED

摘要:

This study evaluated the predictive factors and prognostic value of new-onset persistent left bundle branch block (LBBB) in patients undergoing transcatheter aortic valve implantation (TAVI) with a balloon-expandable valve. The predictors of persistent (vs. transient or absent) LBBB after TAVI with a balloon-expandable valve and its clinical consequences are unknown. A total of 202 consecutive patients with no baseline ventricular conduction disturbances or previous permanent pacemaker implantation (PPI) who underwent TAVI with a balloon-expandable valve were included. Patients were on continuous electrocardiographic (ECG) monitoring during hospitalization and 12-lead ECG was performed daily until hospital discharge. No patient was lost at a median follow-up of 12 (range: 6 to 24) months, and ECG tracing was available in 97% of patients. The criteria for PPI were limited to the occurrence of high-degree atrioventricular block (AVB) or severe symptomatic bradycardia. New-onset LBBB was observed in 61 patients (30.2%) after TAVI, and had resolved in 37.7% and 57.3% at hospital discharge and 6- to 12-month follow-up, respectively. Baseline QRS duration (p = 0.037) and ventricular depth of the prosthesis (p = 0.017) were independent predictors of persistent LBBB. Persistent LBBB at hospital discharge was associated with a decrease in left ventricular ejection fraction (p = 0.001) and poorer functional status (p = 0.034) at 1-year follow-up. Patients with persistent LBBB and no PPI at hospital discharge had a higher incidence of syncope (16.0% vs. 0.7%; p = 0.001) and complete AVB requiring PPI (20.0% vs. 0.7%; p < 0.001), but not of global mortality or cardiac mortality during the follow-up period (all, p > 0.20). New-onset LBBB was the only factor associated with PPI following TAVI (p < 0.001). Up to 30% of patients with no prior conduction disturbances developed new LBBB following TAVI with a balloon-expandable valve, although it was transient in more than one third. Longer baseline QRS duration and a more ventricular positioning of the prosthesis were associated with a higher rate of persistent LBBB, which in turn determined higher risks for complete AVB and PPI, but not mortality, at 1-year follow-up.

收起

展开

DOI:

10.1016/j.jacc.2012.07.035

被引量:

60

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(807)

参考文献(0)

引证文献(60)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读