Vena cava filter practices of a regional vascular surgery society.

来自 PUBMED

作者:

Friedell MLNelson PRCheatham ML

展开

摘要:

Vena cava filter (VCF) use in the United States has increased dramatically with prophylactic indications for placement and the availability of low-profile retrievable devices, which are overtaking the filter market. We surveyed the practice patterns of a large group of vascular surgeons from a regional vascular surgery society to see whether they mirrored current national trends. A 17-question online VCF survey was offered to all members of the Southern Association of Vascular Surgery. The responses were analyzed using the χ(2) goodness of fit tests. Of the 276 members surveyed, 126 (46%) responded, with 118 (93%) indicating that they placed filters during their practice. Highly significant differences were identified with each question (at least P < 0.002). Regarding the inferior vena cava, the preferred permanent filters were the Greenfield (31%), the TrapEase (15%), the Vena Tech (5%), and a variety of retrievable devices (49%). Fifty percent of the respondents placed retrievable filters selectively; 26% always placed them; and 24% never did. Filters were placed for prophylactic indications <50% of the time by 63% of the respondents. Overall, retrievable filters (when not used as permanent filters) were removed <25% of the time by 64% of the respondents and <50% of the time by 78% of the respondents. The femoral vein was the preferred access site for 84% of the respondents. Major complications were few but included filter migration to the atrium (one), atrial perforation (one), abdominal pain requiring surgical filter removal (two), inferior vena cava thrombosis (12 vena cava thrombosis--4 due to TrapEase filters), strut fracture with embolization to heart or lungs (three Bard retrievable filters), and severe tilting precluding percutaneous retrieval and protection from pulmonary emboli (8 filters with severe tilt--7 of which were Bard). Of the respondents, 59% had never placed a superior vena cava filter, and 28% had placed five or fewer. Although VCF insertion overall appears safe, some complications are specific to biconical and certain retrievable filters. Given the low removal rate and lack of long-term experience with retrievable filters, routine use of these devices as permanent filters should be questioned. If used on a temporary basis, there should be a plan for filter removal at the time of implantation.

收起

展开

DOI:

10.1016/j.avsg.2011.11.033

被引量:

3

年份:

2012

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(729)

参考文献(0)

引证文献(3)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读