Prospective model-based comparison of different laryngoscopes for difficult intubation in infants.

来自 PUBMED

作者:

Kalbhenn JBoelke AKSteinmann D

展开

摘要:

Difficult intubation in infants is uncommon but may be a challenge for the anesthesiologist. Many optical-assisted techniques are available to ease endotracheal placement of tube but have not been systemically evaluated for pediatric practice. The study was performed to compare conventional pediatric Macintosh - with different optical laryngoscopes in difficult endotracheal intubation in infants. We hypothesized that inexperienced anesthetists would perform more successful with optical devices and that differences between the devices would be found. In this randomized controlled study, 30 anesthesia residents performed endotracheal intubation in an infant model of difficult airway presenting with airway obstruction and neck immobilization. Primary endpoints were intubation success rate and intubation time. Beyond that glottis view, dental trauma and difficulty of technique were evaluated and measured by a study observer. Macintosh, Airtraq(®), Storz DCI(®) -, and Gyrus Infant Bullard(®) laryngoscopes were used in random order. After standardized briefing every resident had three attempts of at most 120 s with every device to place a 3-mm tube into the trachea. Glottis view and difficulty of technique were rated by the residents using classification of Cormack/Lehane and Visual Analogue Scale (VAS; 0 = easy to 10 = very difficult). Success rate was 41% with conventional Macintosh, 43% with Airtraq(®), 62% with Storz DCI(®), and 100% with Bullard(®) laryngoscopes. Median time from passing the lips to first ventilation was 67 s (Storz DCI(®) laryngoscope), 54 s (Macintosh laryngoscope), 45 s (Airtraq(®) laryngoscope), and 21 s (Bullard(®) laryngoscope), respectively. Dental trauma did not occur with Bullard(®) laryngoscope and was frequent with Storz DCI(®) laryngoscope (39%) and Macintosh laryngoscope (42%). Glottis view was best with Bullard(®) laryngoscope (Grade 1 in 100%) and worst with Macintosh laryngoscope (Grade 1 in 2%). Difficulty of technique was rated with a VAS score of 2 (Bullard(®) laryngoscope), 4.5 (Storz DCI(®) laryngoscope) and 6 (Airtraq(®) - and Macintosh laryngoscopes). Inexperienced anesthetists have higher success rates and shorter intubation times with optical-assisted laryngoscopes compared with conventional Macintosh laryngoscope. Gyrus Infant Bullard(®) laryngoscope significantly undertakes best success rate and shortest intubation time with mildest impact to maxillary dents and easiest technique. Our findings support the hypothesis that optical laryngoscopes can be used successfully by inexperienced anesthetists in simulated difficult pediatric airway conditions.

收起

展开

DOI:

10.1111/j.1460-9592.2012.03890.x

被引量:

4

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(1839)

参考文献(0)

引证文献(4)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读