Feasibility, accuracy, and reproducibility of real-time full-volume 3D transthoracic echocardiography to measure LV volumes and systolic function: a fully automated endocardial contouring algorithm in sinus rhythm and atrial fibrillation.

来自 PUBMED

摘要:

To assess the feasibility, accuracy, and reproducibility of real-time full-volume 3-dimensional transthoracic echocardiography (3D RT-VTTE) to measure left ventricular (LV) volumes and ejection fraction (EF) using a fully automated endocardial contouring algorithm and to identify and automatically correct the contours to obtain accurate LV volumes in sinus rhythm and atrial fibrillation (AF). 3D transthoracic echocardiography is not used routinely to quantify LV volumes and EF. A fully automated workflow using RT-VTTE may improve clinical adoption. RT-VTTE was performed and 3D EF and volumes obtained using an automated trabecular endocardial contouring algorithm; an automated correction was applied to track the compacted myocardium. Cardiac magnetic resonance (CMR) and 2-dimensional biplane Simpson method were the reference standard. Ninety-one patients (67 in normal sinus rhythm [NSR], 24 in AF) were included. Among all NSR patients, there was excellent correlation between RT-VTTE and CMR for end-diastolic volume (EDV), end-systolic volume (ESV), and EF (r = 0.90, 0.96, and 0.98, respectively; p < 0.001). In patients with EF ≥50% (n = 36), EDV and ESV were underestimated by 10.7 ± 17.5 ml (p = 0.001) and by 4.1 ± 6.1 ml (p < 0.001), respectively. In those with EF <50% (n = 31), EDV and ESV were underestimated by 25.7 ± 32.7 ml (p < 0.001) and by 16.2 ± 24.0 ml (p = 0.001). Automated contour correction to track the compacted myocardium eliminated mean volume differences between RT-VTTE and CMR. In patients with AF, LV volumes and EF were accurate by RT-VTTE (r = 0.94, 0.94, and 0.91 for EDV, ESV, and EF, respectively; p < 0.001). Automated 3D LV volumes and EF were highly reproducible. Rapid, accurate, and reproducible EF can be obtained by RT-VTTE in NSR and AF patients by using an automated trabecular edge contouring algorithm. Furthermore, automated contour correction to detect the compacted myocardium yields accurate and reproducible 3D LV volumes.

收起

展开

DOI:

10.1016/j.jcmg.2011.12.012

被引量:

31

年份:

2012

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(751)

参考文献(0)

引证文献(31)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读