Reading performance after implantation of a modified corneal inlay design for the surgical correction of presbyopia: 1-year follow-up.

来自 PUBMED

作者:

Dexl AKSeyeddain ORiha WHohensinn MRückl THitzl WGrabner G

展开

摘要:

To evaluate change in different reading performance parameters after monocular ACI7000PDT corneal inlay implantation for the improvement of near and intermediate vision. Prospective, interventional case series. Twenty-four patients were scheduled for corneal inlay implantation in the nondominant eye in a university outpatient surgery center. Naturally emmetropic and presbyopic patients between 45 and 60 years of age, with uncorrected distance visual acuity of at least 20/20 in both eyes, without any additional ocular pathology were eligible for inclusion. Bilateral uncorrected reading acuity, mean and maximum reading speed, and smallest log-scaled print size were evaluated with the standardized Radner Reading Charts. Measurements of reading parameters and reading distance were performed with the Salzburg Reading Desk (SRD). Minimum postoperative follow-up was 12 months. The reading desk results showed significant changes in each parameter tested. After 12 months the mean reading distance changed from the preoperative value of 46.7 cm (95% CI: 44.1-49.3) to 42.8 cm (95% CI: 40.3-45.3, P < .004), and the mean reading acuity "at best distance" improved from 0.33 logRAD (95% CI: 0.27-0.39) to 0.24 logRAD (95% CI: 0.20-0.28, P < .005). Mean reading speed increased from 141 words per minute (wpm, 95% CI: 133-150) to 156 wpm (95% CI: 145-167, P < .003), maximum reading speed increased from 171 wpm (95% CI: 159-183) to 196 wpm (95% CI: 180-212, P = .001), and the smallest print size improved from 1.50 mm (95% CI: 1.32-1.67) to 1.12 mm (95% CI: 1.03-1.22, P < .001). After ACI7000PDT implantation, there were significant changes in all tested reading performance parameters in emmetropic presbyopic patients. These 1-year results indicate that the inlay seems to be an effective treatment for presbyopia.

收起

展开

DOI:

10.1016/j.ajo.2011.08.044

被引量:

7

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(258)

参考文献(0)

引证文献(7)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读