Macular ganglion cell layer imaging in preperimetric glaucoma with speckle noise-reduced spectral domain optical coherence tomography.
摘要:
To visualize the macular ganglion cell layer (GCL) and measure its thickness in normal eyes and eyes with preperimetric glaucoma, using speckle noise-reduced spectral domain optical coherence tomography (SD-OCT). Retrospective consecutive case series. Thirty-seven eyes of 37 patients with preperimetric glaucoma and 39 normal eyes of 39 volunteers. Vertical and horizontal SD-OCT B-scan images were acquired with minimal speckle noise by using eye-tracking to obtain and average 50 B-scans at each identical location of interest. B-scan images were manually analyzed for GCL, retinal nerve fiber layer (RNFL), and inner plexiform layer shapes and thicknesses in the macula. Macular GCL images and thickness in normal eyes and in eyes with preperimetric glaucoma. The macular GCL was clearly seen on speckle noise-reduced SD-OCT images in normal eyes and eyes with preperimetric glaucoma. In each eye with preperimetric glaucoma, thinning of the macular GCL was visually apparent, particularly on vertical scans. The mean regional macular GCL was most severely thinned in the inferior perifoveal region, where its thickness was <70% of its normal thickness in 30 (81.1%) of the 37 eyes and <50% of its normal thickness in 13 (35.1%) of the 37 eyes. When the sensitivity and specificity for detecting abnormal thinning (outside the lower limit of 99% confidence interval [CI] for the means in the 39 normal eyes) in at least one 0.5-mm segment or sector were compared, the macular GCL on vertical B-scans exhibited higher sensitivity (81.1%) than the other layers on vertical B-scans (99% CI, 5.4%-59.5%; P = 0.00075-0.02100), the macular GCL (99% CI, 40.5%; P = 0.00027) on horizontal B-scans, the other layers (99% CI, 5.4%-48.6%; P<0.00048-0.00400) on horizontal B-scans, and circumpapillary RNFL automatically measured on SD-OCT (54.1%; P = 0.021), and scanning laser polarimetry with variable corneal compensation (24.3%; P = 0.00095). All the macular layers on both the vertical and horizontal B-scans and circumpapillary RNFL thickness exhibited comparable specificity (91.4-100.0%, statistically not different). Speckle noise-reduced SD-OCT imaging allowed clear visualization and measurement of the macular GCL, which was severely thinned in eyes with preperimetric glaucoma. Proprietary or commercial disclosure may be found after the references.
收起
展开
DOI:
10.1016/j.ophtha.2011.06.015
被引量:
年份:
1970


通过 文献互助 平台发起求助,成功后即可免费获取论文全文。
求助方法1:
知识发现用户
每天可免费求助50篇
求助方法1:
关注微信公众号
每天可免费求助2篇
求助方法2:
完成求助需要支付5财富值
您目前有 1000 财富值
相似文献(1797)
参考文献(0)
引证文献(35)
来源期刊
影响因子:暂无数据
JCR分区: 暂无
中科院分区:暂无