-
Persistent coronary no flow after wire insertion is an early and readily available mortality risk factor despite successful mechanical intervention in acute myocardial infarction: a pooled analysis from the STRATEGY (Single High-Dose Bolus Tirofiban and S
These studies sought to investigate the impact on mortality of coronary flow after passage of the wire through the culprit vessel in patients with ST-segment elevation myocardial infarction (STEMI) undergoing mechanical reperfusion.
Reduced spontaneous coronary flow before percutaneous coronary intervention influences mortality in patients with STEMI. Response to vessel wiring in patients with an occluded coronary artery before intervention might further discriminate outcomes irrespective of pre- and post-intervention coronary flow.
Data from the STRATEGY (Single High-Dose Bolus Tirofiban and Sirolimus-Eluting Stent Versus Abciximab and Bare-Metal Stent in Acute Myocardial Infarction) and MULTISTRATEGY (Multicenter Evaluation of Single High-Dose Bolus Tirofiban Versus Abciximab With Sirolimus-Eluting Stent or Bare-Metal Stent in Acute Myocardial Infarction Study) trials were pooled: of 919 index procedures, 902 films (98%) were technically adequate for core laboratory TIMI (Thrombolysis In Myocardial Infarction) flow determination.
TIMI flow grade 0 was present before percutaneous coronary intervention in 59% of infarct vessels, TIMI flow grade 1 to 2 was found in 21%, whereas the remainder of infarct arteries presented with TIMI flow grade 3. In 49% of patients who showed persistent TIMI flow grade 0 after wire insertion (AWI), mortality was higher at 30 days (5.3%) and 1 year (9.4%) compared with patients in whom TIMI flow grade before percutaneous coronary intervention was either >0 (0.8%; p < 0.003 and 3.6%, p < 0.008) or improved from 0 AWI (1.5%, p < 0.04 and 3.6%, p < 0.02). After correcting for multiple imbalances, including baseline and final flow, persistent TIMI flow grade 0 AWI remained associated at 30 days to 2-fold (risk ratio [RR]: 2.1, 95% confidence interval [CI]: 1.08 to 5.00; p = 0.038) and at 1 year to almost 3-fold increases of mortality (RR: 2.7, 95% CI: 1.3 to 5.6; p = 0.008).
STEMI patients displaying persistent no-flow AWI have a lower survival rate despite an apparently successful mechanical intervention. As an early marker for high residual mortality risk, persistent no-flow AWI may qualify STEMI patients for dedicated pharmacomechanical treatment strategies.
Valgimigli M
,Campo G
,Malagutti P
,Anselmi M
,Bolognese L
,Ribichini F
,Boccuzzi G
,de Cesare N
,Rodriguez AE
,Russo F
,Moreno R
,Biondi-Zoccai G
,Penzo C
,Díaz Fernández JF
,Parrinello G
,Ferrari R
... -
《-》
-
Prediction of 1-year clinical outcomes using the SYNTAX score in patients with acute ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention: a substudy of the STRATEGY (Single High-Dose Bolus Tirofiban and Sirolim
This study sought to evaluate the impact of SYNTAX score (SXscore), and compare its performance in isolation and combination with the PAMI (The Primary Angioplasty in Myocardial Infarction Study) score, for the prediction of 1-year clinical outcomes in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention.
Patients with STEMI were excluded from the original SYNTAX score (SXscore) algorithm. Therefore, the utility of using the SXscore in this patient group remains undefined.
SXscore was calculated retrospectively in 807 patients with STEMI enrolled in the randomized STRATEGY (Single High-Dose Bolus Tirofiban and Sirolimus-Eluting Stent Versus Abciximab and Bare-Metal Stent in Acute Myocardial Infarction) and MULTISTRATEGY (Multicenter Evaluation of Single High-Dose Bolus Tirofiban Versus Abciximab With Sirolimus-Eluting Stent or Bare-Metal Stent in Acute Myocardial Infarction Study) clinical trials. Clinical outcomes of all-cause death, reinfarction, and clinically driven target vessel revascularization were subsequently stratified according to SXscore tertiles: SX(LOW) ≤ 9 (n = 311), 9 < SX(MID) ≤ 16 (n = 234), SX(HIGH) >16 (n = 262).
At 1-year follow-up, all clinical outcomes including mortality, mortality/reinfarction, major adverse cardiac events (MACE) (a composite of all-cause death, reinfarction and target vessel revascularization), and definite, definite/probable, and any stent thrombosis were all significantly higher in patients in the highest SXscore tertile. SXscore was identified as an independent predictor of mortality, MACE, and stent thrombosis out to 1-year follow-up. The combination SYNTAX-PAMI score led to a net reclassification improvement of 15.7% and 4.6% for mortality and MACE, respectively. The C-statistics for the SXscore, PAMI score, and the combined SYNTAX-PAMI score were 0.65, 0.81, and 0.73 for 1-year mortality, and 0.68, 0.64, and 0.69 for 1-year MACE, respectively.
SXscore does have a role in the risk stratification of patients with STEMI having primary percutaneous coronary intervention; however, this ability can be improved through a combination with clinical variables. (Multicentre 2×2 Factorial Randomised Study Comparing Tirofiban Versus Abciximab and SES Versus BMS in AMI; NCT00229515).
Garg S
,Sarno G
,Serruys PW
,Rodriguez AE
,Bolognese L
,Anselmi M
,De Cesare N
,Colangelo S
,Moreno R
,Gambetti S
,Monti M
,Bristot L
,Bressers M
,Garcia-Garcia HM
,Parrinello G
,Campo G
,Valgimigli M
,STRATEGY and MULTISTRATEGY Investigators
... -
《-》
-
Comparison of newer-generation drug-eluting with bare-metal stents in patients with acute ST-segment elevation myocardial infarction: a pooled analysis of the EXAMINATION (clinical Evaluation of the Xience-V stent in Acute Myocardial INfArcTION) and COMFO
This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI).
Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES.
Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year.
Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS.
Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up.
Sabaté M
,Räber L
,Heg D
,Brugaletta S
,Kelbaek H
,Cequier A
,Ostojic M
,Iñiguez A
,Tüller D
,Serra A
,Baumbach A
,von Birgelen C
,Hernandez-Antolin R
,Roffi M
,Mainar V
,Valgimigli M
,Serruys PW
,Jüni P
,Windecker S
... -
《-》
-
Impact of lesion length and vessel size on clinical outcomes after percutaneous coronary intervention with everolimus- versus paclitaxel-eluting stents pooled analysis from the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent
The aim of this study was to investigate the impact of reference vessel diameter (RVD) and lesion length (LL) on the relative safety and efficacy of everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES).
Lesion length and RVD are well-known predictors of adverse events after percutaneous coronary intervention.
Patient-level data were pooled from the randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) trials. Quantitative angiographic core laboratory data were available for 6,183 patients randomized to EES (n = 3,944) or PES (n = 2,239). Long lesions and small vessels were defined as LL >median (13.4 mm) and RVD ≤median (2.65 mm), respectively. Major adverse cardiac events (MACE) (consisting of cardiac death, myocardial infarction, or ischemia-driven target lesion revascularization) were assessed at 2 years, according to stent type in 3 groups: short lesions in large vessels (group A, n = 1,297); long lesions or small vessels but not both (group B, n = 2,981); and long lesions in small vessels (group C, n = 1,905).
The pooled 2-year MACE rates were 5.6%, 8.2%, and 10.4% in Groups A, B, and C, respectively (p < 0.0001). There was no significant interaction between lesion group and stent type (p = 0.64), indicating lower MACE with EES compared with PES regardless of LL and RVD. However, the absolute difference was largest in Groups B and C. In Group A, 2-year MACE rates were not significantly different between EES and PES (4.8% vs. 7.0%, respectively, p = 0.11). In contrast, EES was associated with lower 2-year rates of MACE in Group B (6.6% vs. 11.2%, p < 0.01) and in Group C (9.1% vs. 12.7%, p = 0.008) as well as lower rates of myocardial infarction, target lesion revascularization, and stent thrombosis. Multivariable analysis confirmed EES versus PES as an independent predictor of freedom from MACE in Groups B and C.
Patients with short lesions in large vessels have low rates of MACE at 2 years after treatment with either EES or PES. In higher-risk patients with long lesions and/or small vessels, EES results in significant improvements in both clinical safety and efficacy outcomes. (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT00180479; SPIRIT IV Clinical Trial: Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT00307047; A Randomized Controlled Trial of Everolimus-eluting Stents and Paclitaxel-eluting Stents for Coronary Revascularization in Daily Practice: The COMPARE Trial; NCT01016041).
Claessen BE
,Smits PC
,Kereiakes DJ
,Parise H
,Fahy M
,Kedhi E
,Serruys PW
,Lansky AJ
,Cristea E
,Sudhir K
,Sood P
,Simonton CA
,Stone GW
... -
《-》
-
A pooled analysis of data comparing sirolimus-eluting stents with bare-metal stents.
Although randomized studies have shown a beneficial effect of drug-eluting stents in reducing the risk of repeated revascularization, these trials were underpowered to compare rates of death and myocardial infarction. The long-term safety of drug-eluting stents has been questioned recently.
We performed a pooled analysis of 1748 patients in four randomized trials evaluating the safety of sirolimus-eluting stents as compared with bare-metal stents. Patient-level data were obtained and analyzed by independent statisticians at two academic institutions. The primary safety end point was survival at 4 years. We tested for heterogeneities in treatment effect in patient subgroups.
The survival rate at 4 years was 93.3% in the sirolimus-stent group, as compared with 94.6% in the bare-metal-stent group (hazard ratio for death, 1.24; 95% confidence interval [CI], 0.84 to 1.83; P=0.28). In the 428 patients with diabetes, a significant difference in the survival rate was observed in favor of the bare-metal-stent group over the sirolimus-stent group (95.6% vs. 87.8%; hazard ratio for death in the sirolimus-stent group, 2.9; 95% CI, 1.38 to 6.10; P=0.008). The lower survival rate among patients with diabetes who were treated with sirolimus-eluting stents was due to increased numbers of deaths from both cardiovascular and noncardiovascular causes. No difference in survival rate was detected among the patients without diabetes. Rates of myocardial infarction and stent thrombosis were similar in the two groups.
In a pooled analysis of data from four trials comparing sirolimus-eluting stents and bare-metal stents, no significant differences were found between the two treatments in rates of death, myocardial infarction, or stent thrombosis. (ClinicalTrials.gov numbers, NCT00233805 [ClinicalTrials.gov] , NCT00381420 [ClinicalTrials.gov] , NCT00232765 [ClinicalTrials.gov] , and NCT00235144 [ClinicalTrials.gov].)
Spaulding C
,Daemen J
,Boersma E
,Cutlip DE
,Serruys PW
... -
《-》