-
Long-term results of Talent endografts for endovascular abdominal aortic aneurysm repair.
Since the introduction of endovascular aneurysm repair (EVAR), long-term follow-up studies reporting single-device results are scarce. In this study, we focus on EVAR repair with the Talent stent graft (Medtronic, Santa Rosa, Calif).
Between July 2000 and December 2007, 365 patients underwent elective EVAR with a Talent device. Patient data were gathered prospectively and evaluated retrospectively. By American Society of Anesthesiologists category, 74% were categories III and IV. Postoperative computed tomography (CT) scanning was performed before discharge, at 3, 12 months, and yearly thereafter. Data are presented according to reporting standards for EVAR.
The mean proximal aortic neck diameter was 27 mm (range, 16-36 mm), with a neck length <15 mm in 31% (data available for 193 patients). Deployment of endografts was successful in 361 of 365 patients (99%). Initially, conversion to laparotomy was necessary in four patients. Primary technical success determined by results from computed tomography (CT) scans before discharge was achieved in 333 patients (91%). Proximal type I endoleaks were present in 28 patients (8%) during follow-up, and 14 of these patients needed additional treatment for type I endoleak. The 30-day mortality for the whole Talent group was 1.1% (4 of 365). Follow-up to 84 months is reported for 24 patients. During follow-up, 122 (33%) patients died; in nine, death was abdominal aortic aneurysm (AAA)-related (including 30-day mortality). Kaplan-Meier estimates revealed primary clinical success rates of 98% at 1 year, 93% at 2 years, 88% at 3 years, 79% at 4 years, 64% at 5 years, 51% at 6 years, and 48% at 7 years. Secondary interventions were performed in 73 of 365 patients (20%). Ten conversions for failed endografts were performed. Life-table yearly risk for AAA-related reintervention was 6%, yearly risk for conversion to open repair was 1.1%, yearly risk for total mortality was 8.9%, and yearly risk for AAA-related mortality was 0.8%.
Initially, technical success of endovascular aneurysm repair (EVAR) using the Talent endograft is high, with acceptable yearly risk for AAA-related mortality and conversion. However, a substantial amount of mainly endovascular reinterventions is necessary during long-term follow-up to achieve these results.
Verhoeven BA
,Waasdorp EJ
,Gorrepati ML
,van Herwaarden JA
,Vos JA
,Wille J
,Moll FL
,Zarins CK
,de Vries JP
... -
《-》
-
Results of standard suprarenal fixation endografts for abdominal aortic aneurysms with neck length ≤10 mm in high-risk patients unfit for open repair and fenestrated endograft.
The aim of this study was to evaluate long-term outcomes of endovascular aneurysm repair (EVAR) using a standard suprarenal fixation endograft in abdominal aortic aneurysms (AAAs) with infrarenal neck length ≤10 mm (short-neck AAA [SN-AAA]).
From 2005 to 2010, data of high-risk patients with SN-AAA, unfit for open repair (OR) and fenestrated EVAR, were prospectively collected. Follow-up was performed by duplex ultrasound and contrast-enhanced ultrasound or computed tomography angiography at 1 month, 6 months, and 12 months and yearly thereafter. The primary end point was AAA-related mortality. Secondary end points were proximal type I endoleak, freedom from reintervention, and AAA shrinkage (>5 mm).
Sixty patients (mean age, 74.9 ± 6.2 years; American Society of Anesthesiologists class 3 [85%] and class 4 [15%]) were enrolled. The mean aneurysm diameter and neck length and diameter were 60.4 ± 12.2 mm, 8.4 ± 1.6 mm, and 23.5 ± 3 mm, respectively. Four (7%) patients were symptomatic and 15 (25%) had rapid AAA enlargement (>5 mm/6 months). Cook Zenith Flex (Cook Medical, Bloomington, Ind) endografts (32) and Medtronic Endurant (Medtronic, Santa Rosa, Calif) endografts (28) were implanted. The mean follow-up was 51 ± 18 months. Survival at 5 years was 70%. There were three (5%) type I endoleaks. One was sealed by endovascular reintervention, and two (3%) underwent conversion to OR for AAA rupture at 8 and 36 months. Both patients died (2/60; 3% AAA-related mortality). Reinterventions were necessary for another five (8%) patients, and they were not proximal neck related. Freedom from reintervention at 5 years was 90%. In 49 (82%) cases, there was AAA shrinkage; the AAA diameter remained stable in nine (15%) and increased in two (3%) cases. Severe proximal angle (α neck angle ≥60 degrees) was associated with type I endoleak (P = .010) and reinterventions (P = .010). The neck length <7 mm (P = .030) was associated with reinterventions (P = .017).
Suprarenal fixation EVAR in SN-AAA with a straight, not wide neck and 7- to 10-mm aortic neck length can be considered safe and effective in patients who are unfit for OR and fenestrated EVAR. For these cases, long-term data showed acceptable results in preventing aneurysm rupture and related mortality.
Gallitto E
,Gargiulo M
,Freyrie A
,Bianchini Massoni C
,Pini R
,Mascoli C
,Faggioli G
,Stella A
... -
《-》
-
One-year multicenter results of 100 abdominal aortic aneurysm patients treated with the Endurant stent graft.
The Endurant (Medtronic, Minneapolis, Minn) is a new stent graft specifically designed to make more patients anatomically eligible for endovascular aneurysm (EVAR). This study presents the 1-year results of 100 consecutive patients with abdominal aortic aneurysms (AAAs) treated with the Endurant stent graft in real-life practice.
All clinical preoperative, operative, postoperative, and 1-year follow-up data of patients with the Endurant stent graft from three tertiary centers were prospectively collected. Patients underwent computed tomographic angiography (CTA) preoperatively, at 1 month, and at 1-year post-EVAR. The first 100 patients with an implantation date at least 1 year before our date of analysis and complete information were included. Clinical data, AAA characteristics, presence of endoleaks, graft migration, and other EVAR-related complications were noted. All values are stated as mean ± SD (range).
This study included 100 patients with AAAs (88 men) with a mean age of 73 ± 8 years (47 to 87 years), an AAA size of 61 ± 10 mm (31 to 93 mm), an AAA volume of 210 ± 122 mL (69 to 934 mL), a proximal neck length of 33 ± 14 mm (9 to 82 mm), and an infrarenal angulation of 44 ± 25° (0°-108°). Nineteen of the 100 included patients had at least one anatomic characteristic that was considered a violation of the instructions for use (IFU) of the Endurant stent graft. A primary technical success was achieved in 98% of the patients (one additional stent placement in renal artery was required; one unplanned aorto-uni-iliac device placed), with no primary type I or III endoleaks or conversions. A secondary technical success was achieved in all cases. The 30-day mortality was 2% and the first postoperative CTA documented 16 endoleaks (16%; 16 type II). One-year follow-up showed three iliac limb occlusions (3%), one infected stent graft (causing a type Ia endoleak), and five endovascular reinterventions (5%; three to treat iliac limb occlusions, one proximal extension cuff; and one stent in the renal artery). The 1-year all-cause mortality rate was 12% (12 patients) and the AAA-related mortality was 3%. The mean AAA size was significantly smaller after 1 year (diameter, 54 ± 11.8 [32-80] mm; P < .01; volume, 173 ± 119 [42-1028] mL; P < .01), and one graft migration >5 mm and 13 endoleaks were noted (12 type II, 1 type I [neck dilatation]).
The treatment of patients with AAAs with the Endurant stent graft seems to be successful and durable during the first year after EVAR. Despite the wider inclusion criteria for the Endurant, and with 19% of our patients treated outside the IFU, the AAA-related mortality, number of type I or III endoleaks, and reintervention rates are comparable to the results of other stent grafts.
van Keulen JW
,de Vries JP
,Dekker H
,Gonçalves FB
,Moll FL
,Verhagen HJ
,van Herwaarden JA
... -
《-》
-
New results with 100 Excluder cases.
Ghotbi R
,Sotiriou A
,Mansur R
《JOURNAL OF CARDIOVASCULAR SURGERY》
-
Results of endovascular repair of infrarenal aortic aneurysms using the Endurant stent graft.
Recent reports showed that the Endurant stent graft (Medtronic Cardiovascular, Santa Rosa, Calif) is safe and effective for endovascular repair of abdominal aortic aneurysms (AAAs). However, due to its relatively recent introduction, only short-term follow-up data are available. This study presents the 4-year results using this device.
All clinical data, including detailed anatomic information of the first 100 consecutive patients treated with the Endurant stent graft for an infrarenal AAA in three Dutch high-volume hospitals, were prospectively collected. Computed tomography angiography was routinely performed before the procedure, ≤ 1 month, and at 1 year post-endovascular aneurysm repair. Thereafter, the imaging modality during yearly follow-up was individualized (duplex ultrasound imaging or computed tomography angiography). Patients were classified as within or outside the instructions for use (IFU) for analysis. Study end points were primary clinical success, overall and AAA-related mortality, and sac morphology changes and endoleak during follow-up. Estimates were obtained using Kaplan-Meier plots.
The study included 100 consecutive patients (88 men) with a median age of 74 years (interquartile range [IQR], 67-79 years) and median AAA diameter of 58 mm (IQR, 55-65 mm), between December 2007 and March 2009. Twenty patients (20%) were treated outside the IFU (18, outside proximal neck IFU, one outside iliac IFU, and one outside both IFUs). Median follow-up was 48 months (IQR, 36-53 months), and no patients were lost. One contained rupture was observed after 1.5 months due to graft infection. No patients had graft migration. Two type Ia endoleaks, 5 type Ib endoleaks, and 15 type II endoleaks were found. Primary clinical success was 97%, 90%, 84% and 77% at 1, 2, 3, and 4 years, respectively. Primary clinical success was comparable for patients treated within or outside IFU (P = .20), although both patients outside iliac IFU needed a secondary iliac intervention. Over time, maximum aneurysm diameter decreased ≥ 5 mm, remained stable, and increased ≥ 5 mm in 58%, 32%, and 10% of the patients, respectively. All-cause mortality was 20% at 4 years, with a 3% AAA-related mortality.
The 4-year follow-up data of the Endurant stent graft for AAA treatment shows its use results in a low AAA-related mortality with adequate prevention of rupture or aneurysm growth. Although patients with very challenging anatomy were treated in our series, primary clinical success rates were comparable for patients treated within and outside the IFU. However, both patients outside the iliac IFU needed a secondary iliac intervention. The knowledge of the present results may aid in improving outcomes in the future.
Zandvoort HJ
,Gonçalves FB
,Verhagen HJ
,Werson DA
,Moll FL
,de Vries JP
,van Herwaarden JA
... -
《-》