[Dosimetry of HDR afterloading machines with Ir-192- und Co-60-sources: comparison of different international protocols].

来自 PUBMED

作者:

Zakaria GASchütte WAzhari HA

展开

摘要:

The air kerma rate in air at a reference distance of 1 meter from the source is the recommended quantity for the specification of gamma ray source in brachytherapy. The absorbed dose for the patients is directly proportional to the air kerma rate. Therefore the air kerma rate should be determined before the first use of the source on patients by a medical physicist who is independent from the source manufacturer. The air kerma rate will then be applied in the calculation of the dose delivered to patients. In practice, high dose rate (HDR) Ir-192 afterloading machines are mostly used in brachytherapy treatment. Currently HDR-Co-60 increasingly come into operation, too. The essential advantage of the use of Co-60 sources is its longer half-life compared to Ir-192. In addition, the purchasing and disposal costs are lower. The use of HDR-Co-60- afterloading machines is also quite interesting for developing countries. This work describes the dosimetry at HDR afterloading machines according to the protocols DIN 6809-2 (1993) in relation to the DGMP-Report 13 (2006), IAEA-TECDOC-1274 (2002) and AAPM Report 41 (1993) with the nuclides Ir-192 and Co-60. We have used 3 different measurement methods (with a cylindrical chamber in solid phantom and in free air and with a well chamber) in dependence of each of the protocols. We have shown that the standard deviations of the measured air kerma rate for the Co-60 source are generally larger than those of the Ir-192 source. The measurements with the well chamber had the lowest deviation from the certificate value. In all protocols and methods the deviations stood for both nuclides by a maximum of about 1.2% for Ir-192 and 2.5% for Co-60-sources respectively.

收起

展开

DOI:

10.1016/j.zemedi.2010.05.001

被引量:

3

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(214)

参考文献(0)

引证文献(3)

来源期刊

Zeitschrift fur Medizinische Physik

影响因子:7.208

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读