Relationships between plasma leptin levels and body composition parameters measured by different methods in postmenopausal women.

来自 PUBMED

作者:

Jürimäe TSudi KJürimäe JPayerl DRüütel K

展开

摘要:

The aim of this study was to determine the effects of body composition measured by different methods with different measurement errors on fasting plasma leptin level in normal body mass and obese postmenopausal women. It was hypothesized that the relationship between plasma leptin concentration and body fat is higher using more sophisticated laboratory methods (dual energy X-ray absorptiometry, DXA) in comparison with field methods (bioelectrical impedance analysis, BIA, or skinfold thickness) for body fat measurement because of the greater precision of DXA measurements. Thirty-five postmenopausal (55-83 years of age) healthy Estonian women were divided into two groups: BMI < 27 kg/m(2) as non obese (n = 18) and BMI> 27 kg/m(2) as obese (n = 17). Body composition was determined using DXA (total body, arms, legs, and trunk fat percent, fat mass, and LBM) and BIA methods. Body fat percent was significantly higher using the DXA method. Subcutaneous adipose tissue distribution was determined by measuring nine skinfold thicknesses. Body fat distribution was defined as the ratio of waist-to-hip (WHR) and waist-to-thigh (WTR) circumferences. Leptin was determined by means of radioimmunoassays. Leptin concentration was not significantly different between groups (19.0 +/- 13.3 and 21.5 +/- 21.5 ng/ml in non obese and obese groups, respectively). Body fat percent and fat weight measured by DXA or BIA methods and all measured skinfold thickness values, except biceps and abdominal, were higher in obese women. Body height did not correlate significantly with leptin concentrations. The relationships between leptin concentration were highest with body weight (r = 0.67) and BMI (r = 0.73) values in the obese group. All measured body fat parameters using DXA or BIA methods correlated significantly with plasma leptin concentration in the obese group. LBM did not influence the leptin concentration in postmenopausal women. Stepwise multiple regression analysis indicated that the body fat percent measured using the DXA method was highly related to plasma leptin concentration in the obese group (63.2%; R(2) x 100). When absolute fat mass parameters were considered, leptin concentration was related to the mass of arms fat tissue in the obese group of women (62.3%). Body fat percent measured by BIA was highly related to plasma leptin concentration in the obese group (63.3%). Only biceps skinfold thickness was related to leptin concentration (22.5% and 58.9%, in the nonobese and obese groups, respectively) from the nine measured skinfold thicknesses. WHR and WTR did not reflect leptin concentration in different groups of postmenopausal women. It was concluded that different methods of body composition estimation generate different correlations with plasma leptin concentration. Body fat percent and especially fat mass measured by DXA are the main predictors relating to plasma leptin concentration in obese, but not in nonobese, postmenopausal women. In addition, fat mass in arms measured by DXA and biceps skinfold thickness were also highly related to leptin concentration.

收起

展开

DOI:

10.1002/ajhb.10178

被引量:

3

年份:

2003

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(1454)

参考文献(0)

引证文献(3)

来源期刊

AMERICAN JOURNAL OF HUMAN BIOLOGY

影响因子:2.944

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读