Retrospective Analysis of Dosimetric Comparison Between Intensity-Modulated Radiation Therapy and Volumetric-Modulated Arc Therapy in Patients With Esophageal Cancer.

来自 PUBMED

作者:

Mishra VYadav RChaudhary SPandey LPandey A

展开

摘要:

Introduction Esophageal cancer is a significant global health concern, with high incidence and mortality rates, particularly in India, where it ranks among the top causes of cancer-related deaths. Radiotherapy plays a critical role in the treatment of advanced-stage esophageal cancer. This study aims to compare the dosimetric outcomes of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) to evaluate their efficacy and safety in managing mid-esophageal carcinoma.  Materials and methods A retrospective study was carried out on thirty patients with middle-third esophageal cancer who received treatment at Rohilkhand Medical College and Hospital, Bareilly, India. The patients, aged between 50 and 70 years (mean age of 66.5 years), were in stages II to III of cancer according to the American Joint Committee on Cancer (AJCC) 2018 guidelines. All patients had histologically confirmed cases of moderately differentiated squamous cell carcinoma. The treatment procedure included immobilization using a thoracic mold, CT simulation with intravenous and oral contrast, and contouring of the gross tumor volume (GTV), clinical target volume (CTV), planning target volume (PTV), and organs at risk (OARs) following the Radiation Therapy Oncology Group (RTOG) 0436 protocol. VMAT planning was done using the Varian Eclipse™ Treatment Planning System, while IMRT planning employed a seven-field non-coplanar beam setup. Comparative virtual IMRT plans were generated for these patients. Both VMAT and IMRT plans were evaluated based on dosimetric parameters for the PTV and OARs. Results Both VMAT and IMRT achieved sufficient PTV coverage, with no statistically significant differences in dosimetric parameters (dose to 99 % volume of PTV, dose to 95 %volume of PTV, maximum dose to PTV, minimum dose to PTV). VMAT demonstrated reduced lung and heart doses compared to IMRT; however, the observed differences were not statistically significant. There was a reduction in lung dose with VMAT when evaluating the dose-volume constraints: volume receiving 15 Gy dose (V15) by 11%, volume receiving 20 Gy dose (V20) by 20%, and volume receiving 25 Gy dose (V25) by 41%, though these differences were not statistically significant. The mean maximum spinal cord dose was significantly lower with VMAT (19.69 Gy) compared to IMRT (30.80 Gy, p=0.01). Heart dosimetry showed slight improvements with VMAT, particularly in volume receiving 30 Gy dose (V30), volume receiving 40 Gy dose (V40), and mean heart dose, though these differences were not statistically significant. Conclusion Both VMAT and IMRT provided similar PTV coverage. VMAT showed a reduction in spinal cord dose, which was statistically significant, and a trend toward lower lung and heart doses, though these differences were not statistically significant. VMAT appears to be an effective option for treating mid-esophageal carcinoma while reducing exposure to critical organs.

收起

展开

DOI:

10.7759/cureus.76981

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(100)

参考文献(0)

引证文献(0)

来源期刊

Cureus

影响因子:0

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读