Left Ventricular Unloading With Impella Versus IABP in Patients With VA-ECMO: A Systematic Review and Meta-Analysis.

来自 PUBMED

作者:

Gandhi KDMoras ECNiroula SLopez PDAggarwal DBhatia KBalboul YDaibes JCorrea ADominguez ACBirati EYBaran DASerrao GMahmood KVallabhajosyula SFox A

展开

摘要:

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) use for circulatory support in cardiogenic shock results in increased left ventricular (LV) afterload. The use of concomitant Impella or intra-aortic balloon pump (IABP) have been proposed as adjunct devices for LV unloading. The authors sought to compare head-to-head efficacy and safety outcomes between the 2 LV unloading strategies. We conducted a search of Medline, EMBASE, and Cochrane databases to identify studies comparing the use of Impella to IABP in patients on VA-ECMO. The primary outcome of interest was in-hospital mortality. The secondary outcomes included transition to durable LV assist devices/cardiac transplantation, stroke, limb ischemia, need for continuous renal replacement therapy, major bleeding, and hemolysis. Pooled risk ratios (RRs) with 95% confidence interval and heterogeneity statistic I2 were calculated using a random-effects model. A total of 7 observational studies with 698 patients were included. Patients on VA-ECMO unloaded with Impella vs IABP had similar risk of short-term all-cause mortality, defined as either 30-day or in-hospital mortality- 60.8% vs 64.9% (RR 0.93 [0.71 to 1.21], I2 = 71%). No significant difference was observed in transition to durable LV assist devices/cardiac transplantation, continuous renal replacement therapy initiation, stroke, or limb ischemia between the 2 strategies. However, the use of VA-ECMO with Impella was associated with increased risk of major bleeding (57.2% vs 39.7%) (RR 1.66 [1.12 to 2.44], I2 = 82%) and hemolysis (31% vs 7%) (RR 4.61 [1.24 to 17.17], I2 = 66%) compared with VA-ECMO, along with IABP. In conclusion, in patients requiring VA-ECMO for circulatory support, the concomitant use of Impella or IABP had comparable short-term mortality. However, Impella use was associated with increased risk of major bleeding and hemolysis.

收起

展开

DOI:

10.1016/j.amjcard.2023.09.023

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(0)

参考文献(0)

引证文献(0)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读