A Monte Carlo dose calculation system for ophthalmic brachytherapy based on a realistic eye model.

来自 PUBMED

摘要:

There is a growing trend towards the adoption of model-based calculation algorithms (MBDCAs) for brachytherapy dose calculations which can properly handle media and source/applicator heterogeneities. However, most of dose calculations in ocular plaque therapy are based on homogeneous water media and standard in-silico ocular phantoms, ignoring non-water equivalency of the anatomic tissues and heterogeneities in applicators and patient anatomy. In this work, we introduce EyeMC, a Monte Carlo (MC) model-based calculation algorithm for ophthalmic plaque brachytherapy using realistic and adaptable patient-specific eye geometries and materials. We used the MC code PENELOPE in EyeMC to model Bebig IsoSeed I25.S16 seeds in COMS plaques and 106 Ru/106 Rh applicators that are coupled onto a customizable eye model with realistic geometry and composition. To significantly reduce calculation times, we integrated EyeMC with CloudMC, a cloud computing platform for radiation therapy calculations. EyeMC is equipped with an evaluation module that allows the generation of isodose distributions, dose-volume histograms, and comparisons with Plaque Simulator three-dimensional dose distribution. We selected a sample of patients treated with 125 I and 106 Ru isotopes in our institution, covering a variety of different type of plaques, tumor sizes, and locations. Results from EyeMC were compared to the original plan calculated by the TPS Plaque Simulation, studying the influence of heterogeneous media composition as well. EyeMC calculations for Ru plaques agreed well with manufacturer's reference data and data of MC simulations from Hermida et al. (2013). Significant deviations, up to 20%, were only found in lateral profiles for notched plaques. As expected, media composition significantly affected estimated doses to different eye structures, especially in the 125 I cases evaluated. Dose to sclera and lens were found to be about 12% lower when considering real media, while average dose to tumor was 9% higher. 106 Ru cases presented a 1%-3% dose reduction in all structures using real media for calculation, except for the lens, which showed an average dose 7.6% lower than water-based calculations. Comparisons with Plaque Simulator calculations showed large differences in dose to critical structures for 106 Ru notched plaques. 125 I cases presented significant and systematic dose deviations when using the default calculation parameters from Plaque Simulator version 5.3.8., which were corrected when using calculation parameters from a custom physics model for carrier-attenuation and air-interface correction functions. EyeMC is a MC calculation system for ophthalmic brachytherapy based on a realistic and customizable eye-tumor model which includes the main eye structures with their real composition. Integrating this tool into a cloud computing environment allows to perform high-precision MC calculations of ocular plaque treatments in short times. The observed variability in eye anatomy among the selected cases justifies the use of patient-specific models.

收起

展开

DOI:

10.1002/mp.15045

被引量:

0

年份:

1970

SCI-Hub (全网免费下载) 发表链接

通过 文献互助 平台发起求助,成功后即可免费获取论文全文。

查看求助

求助方法1:

知识发现用户

每天可免费求助50篇

求助

求助方法1:

关注微信公众号

每天可免费求助2篇

求助方法2:

求助需要支付5个财富值

您现在财富值不足

您可以通过 应助全文 获取财富值

求助方法2:

完成求助需要支付5财富值

您目前有 1000 财富值

求助

我们已与文献出版商建立了直接购买合作。

你可以通过身份认证进行实名认证,认证成功后本次下载的费用将由您所在的图书馆支付

您可以直接购买此文献,1~5分钟即可下载全文,部分资源由于网络原因可能需要更长时间,请您耐心等待哦~

身份认证 全文购买

相似文献(0)

参考文献(0)

引证文献(0)

来源期刊

-

影响因子:暂无数据

JCR分区: 暂无

中科院分区:暂无

研究点推荐

关于我们

zlive学术集成海量学术资源,融合人工智能、深度学习、大数据分析等技术,为科研工作者提供全面快捷的学术服务。在这里我们不忘初心,砥砺前行。

友情链接

联系我们

合作与服务

©2024 zlive学术声明使用前必读